Flow Pack
io.github.Nero-Engine/flow-pack
MCP server OK 10 tools
Live heat pump planning checks and flood warnings, pipe and heat sizing, gas records for plumbers
Technical sheet
- Author
- Nero-Engine (registry namespace)
- Repository
- github.com/Nero-Engine/flow-pack-mcp
- Site
- flow-pack.nerolabs.workers.dev/docs
- Version
- 1.2.0
- Transport
- Streamable HTTP
- Authentication
- None (observed by our test)
- Server address
- https://flow-pack.nerolabs.workers.dev/mcp Streamable HTTP
- Tools
- 10
- Categories
- —
- Last updated
- 27 Nov 2026
- Published
- 27 Nov 2026
Badge for your README
Free, for every entry. It links back to this entry and shows “tested OK” as long as our latest test succeeded.
[](https://latlas.dev/en/mcp/io.github.Nero-Engine/flow-pack)<a href="https://latlas.dev/en/mcp/io.github.Nero-Engine/flow-pack"><img src="https://latlas.dev/badge/fiche/io.github.Nero-Engine/flow-pack.svg?lang=en" alt="Listed on L’Atlas" height="20"></a>Our tests
Every week: initialize then tools/list, without credentials, never calling a tool. Method
- Address
- https://flow-pack.nerolabs.workers.dev/mcp
- Last result
- OK 28 Nov 2026, 10:10
- Response time
- 277 ms (initialize + tools/list)
- Protocol version
- 2025-06-18
- Announced name
- nerolabs-flow-pack 1.2.0
- Tools
- 10
History
| Date | Result | Response | Tools |
|---|---|---|---|
| 28 Nov 2026, 10:10 | OK | 277 ms | 10 |
Exposed tools (10, from tools/list, 28 Nov 2026)
list_capabilities
What Flow Pack can do
Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.
No parameters.
size_pipe
Water or gas pipe size, velocity and pressure loss
Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metre and in total, and the pressure left at the outlet if you give the supply pressure. Gas: flow from the gross heat input of the appliances fed, pressure drop against the 1 mbar natural gas (2.5 mbar LPG) allowance, with a meter capacity warning. Returns `recommended` (smallest size that passes), `sizes_considered`, `must_check` (points the engineer confirms) and sources. Calculated from fluid physics (Darcy-Weisbach); no BS EN 806 or BS 6891 tables are reproduced. Typical calls: {"medium":"gas","heat_input_kw_gross":30,"run_length_m":12,"fittings":{"elbows":5}} or {"medium":"water","service":"cold","outlets":[{"type":"bath"},{"type":"kitchen_sink"},{"type":"basin"},{"type":"wc"},{"type":"shower_mixer"}],"run_length_m":15,"supply_pressure_bar":2.5,"height_rise_m":3}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| medium | enum: "water" | "gas" | yes | |
| run_length_m | number | yes | Measured pipe length, metres (from the meter for gas, from the stop tap or cylinder for water). |
| material | enum: "copper" | "plastic" | "mdpe" | "steel" | "csst" | no | Water: copper (default), plastic, mdpe. Gas: copper (default), steel, csst. |
| pipe_size_mm | number | no | Check only this nominal size. |
| fittings | object | no | Count of fittings on the run. If left out, 30% is added to the length instead (or fittings_allowance_percent). |
| fittings_allowance_percent | number | no | Length added for fittings when they are not counted. Default 30. |
| service | enum: "cold" | "hot" | no | Water only. Default cold. |
| outlets | array<object> | no | Water only: outlets this pipe feeds. |
| simultaneous_outlets | number | no | Water only: how many outlets run at once. Default: square root of the number of outlets, rounded. |
| design_flow_l_s | number | no | Water only: design flow in litres a second, if known (overrides outlets). |
| supply_pressure_bar | number | no | Water only: working pressure at the start of the run (measured with water flowing). |
| min_pressure_at_outlet_bar | number | no | Water only: pressure needed at the end. Default 1.0 bar. |
| height_rise_m | number | no | Water only: height gained from start to outlet (negative if it falls). |
| water_temp_c | number | no | Water only. Default 10 cold, 60 hot. |
| max_velocity_m_s | number | no | Water only. Default 1.5. |
| gas | enum: "natural_gas" | "lpg_propane" | no | Gas only. Default natural_gas. |
| heat_input_kw_gross | number | no | Gas only: total gross heat input of every appliance this pipe feeds (data plate). |
| heat_input_kw_net | number | no | Gas only: if only the net figure is known. |
| gas_flow_m3_h | number | no | Gas only: gas flow, if already known. |
| allowed_drop_mbar | number | no | Gas only. Default 1 natural gas, 2.5 LPG. |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
size_heat_source
Room by room heat loss, boiler and heat pump size
Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing also checks the hot water load (flow x temperature rise). Give each room's type, size and its walls, windows, roof and floor with U values, or construction presets for indicative values. Returns per-room losses with every element's working, the total, the size, `status` (indicative when presets were used), `must_check` and sources. Typical call: {"heat_source":"heat_pump","outside_design_temp_c":-3,"rooms":[{"name":"Lounge","type":"living","floor_area_m2":20,"elements":[{"type":"wall","area_m2":7.8,"construction":"cavity_wall_unfilled"},{"type":"window","area_m2":1.8,"construction":"double_glazed_old"}]}]}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| heat_source | enum: "combi_boiler" | "system_boiler" | "regular_boiler" | "heat_pump" | no | Default combi_boiler. |
| outside_design_temp_c | number | no | Local outside design temperature. Default -3. |
| rooms | array<object> | yes | Up to 40 rooms. |
| margin_percent | number | no | Added to the heating load. Default 10 for boilers, 0 for heat pumps. |
| hot_water_flow_l_min | number | no | Combi: wanted hot water flow. Default 12. |
| hot_water_temp_rise_c | number | no | Combi: temperature rise. Default 35. |
| cylinder_litres | number | no | System or regular boiler: cylinder size. Default 150. |
| reheat_hours | number | no | Wanted reheat time. Default 1. |
| hot_water_priority | boolean | no | Default true (reheat load not added). |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
size_radiators
Radiator size per room, including at heat pump temperatures
For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls short, the water flow per radiator, indicative lengths by panel type, and with compare_flow_temp_c how much bigger radiators must be at a lower flow temperature (for example 70 C boiler to 45 C heat pump). Typical call: {"flow_temp_c":45,"rooms":[{"name":"Lounge","heat_loss_w":1500,"existing_rated_output_w":1800}],"compare_flow_temp_c":70}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| flow_temp_c | number | no | Default 70. |
| return_temp_c | number | no | Default flow minus 10 (minus 5 at 55 C or lower). |
| rooms | array<object> | yes | |
| compare_flow_temp_c | number | no | |
| compare_return_temp_c | number | no | |
| radiator_exponent | number | no | Default 1.3. |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
check_notifiable_work
Is this work notifiable, and who can do it?
For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Water Fittings Regulations, regulation 5)? Returns, per job, who can do it, the self-certification route (competent person scheme within 30 days, or building control before starting) and what to do next, including CO alarm and Boiler Plus rules. Typical call: {"nation":"england","work":["gas_boiler_replacement","unvented_cylinder_new"]}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| nation | enum: "england" | "wales" | no | Default england. |
| work | array<enum: "gas_boiler_new" | "gas_boiler_replacement" | "gas_fire_or_appliance" | "gas_cooker" | "gas_pipework" | "gas_service_or_safety_check" | "gas_meter_move" | "oil_boiler_new_or_replacement" …> | yes | One or more jobs. |
| water_approved_contractor | boolean | no | True if the installer is a water approved contractor (for example WaterSafe). |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
check_gas_record
Check a gas safety record or commissioning record before issuing it
Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate off the rated input, meter pressure out of range, an unsafe appliance marked safe, and the correct next due date (keeping the anniversary for checks done up to 2 months early). Gas safety record fields: property_address, landlord_name, landlord_address, engineer_name, gas_safe_registration_number, engineer_licence_number, check_date, previous_record_expiry_date, next_check_due, engineer_signature, tightness_test_passed, emergency_control_accessible, meter_standing_pressure_mbar, meter_working_pressure_mbar, appliances[] {type, make, model, location, flue_type, flue_check_passed, ventilation_satisfactory, safety_devices_ok, co_ppm, co2_percent, co_co2_ratio, rated_heat_input_kw_gross, measured_gas_rate_m3_h, inlet_working_pressure_mbar, status (safe, ncs, at_risk, immediately_dangerous), safe_to_use, action_taken}. Commissioning fields: property_address, engineer_name, commissioning_date, boiler_type, system_flushed, inhibitor_added, inhibitor_name, filter_fitted, water_hardness_ppm, scale_reducer_fitted, condensate_external_pipe_mm, controls_time_and_temperature, combi_extra_measure, co_alarm_fitted, building_regs_notified, dhw_flow_l_min, dhw_temp_rise_c, appliances[] {make, model, serial_number, co_ppm, co2_percent, min_rate {co_ppm, co2_…
| Parameter | Type | Required | Description |
|---|---|---|---|
| record_type | enum: "gas_safety_record" | "commissioning" | yes | |
| record | object | yes | The filled fields (see the description). |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
emergency_triage
Emergency triage for leaks, bursts, no heat, gas smell or CO alarm
For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an `urgency` value of routine, soon or emergency that matches Nero Work's three job speeds, raised for water near electrics, a bulging ceiling, a vulnerable person in the cold, or water that cannot be stopped. Also returns `nero_work_job` (urgency, category, summary) ready to post. Typical call: {"situation":"no_heat","vulnerable_people":true,"outside_temp_c":2,"other_heating_available":false}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| situation | enum: "gas_smell" | "co_alarm" | "co_symptoms" | "burst_pipe" | "leak" | "water_through_ceiling" | "no_heat" | "no_hot_water" … | yes | |
| nation | enum: "england" | "wales" | "scotland" | "northern_ireland" | no | Changes the gas emergency number for Northern Ireland. |
| vulnerable_people | boolean | no | Elderly, very young, disabled or medically vulnerable person in the home. |
| outside_temp_c | number | no | |
| water_near_electrics | boolean | no | |
| ceiling_bulging | boolean | no | |
| water_stopped | boolean | no | Has turning off the stop tap or valve stopped the water? |
| pipe_split | boolean | no | |
| other_heating_available | boolean | no | |
| only_toilet | boolean | no | |
| sewage_inside | boolean | no | |
| trade | object | no | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
property_check
Live planning check for a heat pump or flue at a postcode
Looks up, live from official open data, what applies at the customer's postcode before an air source heat pump, a new boiler flue or external pipework: listed buildings, conservation areas, Article 4 directions, World Heritage Sites, National Landscapes, scheduled monuments and flood risk zones (planning.data.gov.uk, England, councils that publish), plus any live Environment Agency flood warnings within 10 km. Returns each constraint found with its source link, whether an air source heat pump is likely permitted development there, what each constraint means for heating and plumbing work, and the council and nation. A constraint not found is not proof of none: the answer says so. Example: {"postcode":"YO1 7HH"}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| postcode | string | yes | The job's full UK postcode. |
flood_warnings
Live flood warnings near a postcode
Reads the Environment Agency real time flood warning service (England, updated every 15 minutes) for flood alerts, flood warnings and severe flood warnings near the customer's postcode, and says what to tell the customer: flood water or a plumbing fault, whether to send an engineer, Floodline's number. Wales, Scotland and Northern Ireland get the link to their own flood service. Use it before emergency_triage when water is coming in. Example: {"postcode":"YO1 7HH","radius_km":10}.
| Parameter | Type | Required | Description |
|---|---|---|---|
| postcode | string | yes | The property's full UK postcode. |
| radius_km | number | no | Search radius, 1 to 50 km. Default 10. |
trade_profile
Check the plumber or heating engineer's business details
Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration (licence_body gas_safe plus the Gas Safe registration number) or the company number. The same shape and reference as Spark Pack, so one business keeps one reference across trades. The same object, given as `trade` to the other tools, prefills records. Flow Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.
| Parameter | Type | Required | Description |
|---|---|---|---|
| trade | object | yes | Optional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack. |
Client compatibility
Based on the transports each client documents as supported; this is not a live test inside the client.
| Client | Documented transports | This server | Source |
|---|---|---|---|
| Claude Code | stdio Streamable HTTP SSE | transport accepted | doc |
| Claude (claude.ai, Claude Desktop, Cowork) | stdio Streamable HTTP SSE | transport accepted | doc |
| ChatGPT (serveurs MCP personnalisés / plugins) | Streamable HTTP SSE | transport accepted | doc |
| Cursor | stdio Streamable HTTP SSE | transport accepted | doc |
| VS Code (GitHub Copilot) | stdio Streamable HTTP SSE | transport accepted | doc |
| Windsurf (documentation redirigée vers Devin Local / Devin CLI) | stdio Streamable HTTP SSE | transport accepted | doc |
| Gemini CLI | stdio Streamable HTTP SSE | transport accepted | doc |
| OpenAI Codex (CLI, extension IDE, app) | stdio Streamable HTTP | transport accepted | doc |
Ready-to-copy configs
Remote address used: https://flow-pack.nerolabs.workers.dev/mcp. Formats taken from each client’s documentation.
claude mcp add --transport http flow-pack https://flow-pack.nerolabs.workers.dev/mcpCustomize > Connectors > + Add > Add custom connector ; Name : flow-pack ; URL : https://flow-pack.nerolabs.workers.dev/mcpchatgpt.com/plugins > + > Add custom MCP server ; Name : flow-pack ; Server URL : https://flow-pack.nerolabs.workers.dev/mcp ; Create as a plugin{
"mcpServers": {
"flow-pack": {
"url": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}{
"mcpServers": {
"flow-pack": {
"type": "http",
"url": "https://flow-pack.nerolabs.workers.dev/mcp",
"tools": ["*"]
}
}
}{
"mcpServers": {
"flow-pack": {
"url": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}{
"mcpServers": {
"flow-pack": {
"httpUrl": "https://flow-pack.nerolabs.workers.dev/mcp"
}
}
}[mcp_servers.flow-pack]
url = "https://flow-pack.nerolabs.workers.dev/mcp"Cite this source
Writing an article or comparison? This entry distinguishes registry information from our measurements. Cite the permanent link and the test date; an OK result is not a security audit or an availability guarantee.
Flow Pack · L’Atlas · Tested on
[Flow Pack — L’Atlas](https://latlas.dev/en/mcp/io.github.Nero-Engine/flow-pack)Source : Registre officiel MCP · retrieved 29 Nov 2026. L’Atlas adds no data beyond this source and its own tests.