L'Atlas / MCP servers / Flow Pack
MCP server

Flow Pack

io.github.Nero-Engine/flow-pack

MCP server OK 10 tools

Get a review See pricing

Live heat pump planning checks and flood warnings, pipe and heat sizing, gas records for plumbers

Technical sheet

Author
Nero-Engine (registry namespace)
Repository
github.com/Nero-Engine/flow-pack-mcp
Site
flow-pack.nerolabs.workers.dev/docs
Version
1.2.0
Transport
Streamable HTTP
Authentication
None (observed by our test)
Server address
https://flow-pack.nerolabs.workers.dev/mcp Streamable HTTP
Tools
10
Categories
—
Last updated
27 Nov 2026
Published
27 Nov 2026

Badge for your README

Listed on L’Atlas

Free, for every entry. It links back to this entry and shows “tested OK” as long as our latest test succeeded.

MarkdownREADME.md
[![Listed on L’Atlas](https://latlas.dev/badge/fiche/io.github.Nero-Engine/flow-pack.svg?lang=en)](https://latlas.dev/en/mcp/io.github.Nero-Engine/flow-pack)
HTML
<a href="https://latlas.dev/en/mcp/io.github.Nero-Engine/flow-pack"><img src="https://latlas.dev/badge/fiche/io.github.Nero-Engine/flow-pack.svg?lang=en" alt="Listed on L’Atlas" height="20"></a>

Our tests

Every week: initialize then tools/list, without credentials, never calling a tool. Method

Address
https://flow-pack.nerolabs.workers.dev/mcp
Last result
OK 28 Nov 2026, 10:10
Response time
277 ms (initialize + tools/list)
Protocol version
2025-06-18
Announced name
nerolabs-flow-pack 1.2.0
Tools
10

History

DateResultResponseTools
28 Nov 2026, 10:10OK277 ms10

Exposed tools (10, from tools/list, 28 Nov 2026)

list_capabilities

What Flow Pack can do

Lists Flow Pack's tools, what it covers (nations, pipe materials, gases, record types, emergency situations) and what it deliberately does not do. Free, needs no input.

No parameters.

size_pipe

Water or gas pipe size, velocity and pressure loss

Sizes a hot or cold water pipe, or a low-pressure gas pipe, and shows the working. Water: design flow (from outlets, with a simple in-use-at-once rule, or a flow you give), velocity against a limit (1.5 m/s default), pressure loss per metre and in total, and the pressure left at the outlet if you give the supply pressure. Gas: flow from the gross heat input of the appliances fed, pressure drop against the 1 mbar natural gas (2.5 mbar LPG) allowance, with a meter capacity warning. Returns `recommended` (smallest size that passes), `sizes_considered`, `must_check` (points the engineer confirms) and sources. Calculated from fluid physics (Darcy-Weisbach); no BS EN 806 or BS 6891 tables are reproduced. Typical calls: {"medium":"gas","heat_input_kw_gross":30,"run_length_m":12,"fittings":{"elbows":5}} or {"medium":"water","service":"cold","outlets":[{"type":"bath"},{"type":"kitchen_sink"},{"type":"basin"},{"type":"wc"},{"type":"shower_mixer"}],"run_length_m":15,"supply_pressure_bar":2.5,"height_rise_m":3}.

ParameterTypeRequiredDescription
mediumenum: "water" | "gas"yes
run_length_mnumberyesMeasured pipe length, metres (from the meter for gas, from the stop tap or cylinder for water).
materialenum: "copper" | "plastic" | "mdpe" | "steel" | "csst"noWater: copper (default), plastic, mdpe. Gas: copper (default), steel, csst.
pipe_size_mmnumbernoCheck only this nominal size.
fittingsobjectnoCount of fittings on the run. If left out, 30% is added to the length instead (or fittings_allowance_percent).
fittings_allowance_percentnumbernoLength added for fittings when they are not counted. Default 30.
serviceenum: "cold" | "hot"noWater only. Default cold.
outletsarray<object>noWater only: outlets this pipe feeds.
simultaneous_outletsnumbernoWater only: how many outlets run at once. Default: square root of the number of outlets, rounded.
design_flow_l_snumbernoWater only: design flow in litres a second, if known (overrides outlets).
supply_pressure_barnumbernoWater only: working pressure at the start of the run (measured with water flowing).
min_pressure_at_outlet_barnumbernoWater only: pressure needed at the end. Default 1.0 bar.
height_rise_mnumbernoWater only: height gained from start to outlet (negative if it falls).
water_temp_cnumbernoWater only. Default 10 cold, 60 hot.
max_velocity_m_snumbernoWater only. Default 1.5.
gasenum: "natural_gas" | "lpg_propane"noGas only. Default natural_gas.
heat_input_kw_grossnumbernoGas only: total gross heat input of every appliance this pipe feeds (data plate).
heat_input_kw_netnumbernoGas only: if only the net figure is known.
gas_flow_m3_hnumbernoGas only: gas flow, if already known.
allowed_drop_mbarnumbernoGas only. Default 1 natural gas, 2.5 LPG.
tradeobjectnoOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

size_heat_source

Room by room heat loss, boiler and heat pump size

Works out the heat loss of each room (fabric U x A x delta T plus ventilation 0.33 x air changes x volume x delta T) and the total, then sizes a combi, system or regular boiler, or a heat pump, to the nearest common size. Combi sizing also checks the hot water load (flow x temperature rise). Give each room's type, size and its walls, windows, roof and floor with U values, or construction presets for indicative values. Returns per-room losses with every element's working, the total, the size, `status` (indicative when presets were used), `must_check` and sources. Typical call: {"heat_source":"heat_pump","outside_design_temp_c":-3,"rooms":[{"name":"Lounge","type":"living","floor_area_m2":20,"elements":[{"type":"wall","area_m2":7.8,"construction":"cavity_wall_unfilled"},{"type":"window","area_m2":1.8,"construction":"double_glazed_old"}]}]}.

ParameterTypeRequiredDescription
heat_sourceenum: "combi_boiler" | "system_boiler" | "regular_boiler" | "heat_pump"noDefault combi_boiler.
outside_design_temp_cnumbernoLocal outside design temperature. Default -3.
roomsarray<object>yesUp to 40 rooms.
margin_percentnumbernoAdded to the heating load. Default 10 for boilers, 0 for heat pumps.
hot_water_flow_l_minnumbernoCombi: wanted hot water flow. Default 12.
hot_water_temp_rise_cnumbernoCombi: temperature rise. Default 35.
cylinder_litresnumbernoSystem or regular boiler: cylinder size. Default 150.
reheat_hoursnumbernoWanted reheat time. Default 1.
hot_water_prioritybooleannoDefault true (reheat load not added).
tradeobjectnoOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

size_radiators

Radiator size per room, including at heat pump temperatures

For each room's heat loss, works out the rated (delta T 50) radiator output needed at the system's flow and return temperatures, using output = rated x (mean water to air difference / 50) ^ 1.3. Shows how far an existing radiator falls short, the water flow per radiator, indicative lengths by panel type, and with compare_flow_temp_c how much bigger radiators must be at a lower flow temperature (for example 70 C boiler to 45 C heat pump). Typical call: {"flow_temp_c":45,"rooms":[{"name":"Lounge","heat_loss_w":1500,"existing_rated_output_w":1800}],"compare_flow_temp_c":70}.

ParameterTypeRequiredDescription
flow_temp_cnumbernoDefault 70.
return_temp_cnumbernoDefault flow minus 10 (minus 5 at 55 C or lower).
roomsarray<object>yes
compare_flow_temp_cnumberno
compare_return_temp_cnumberno
radiator_exponentnumbernoDefault 1.3.
tradeobjectnoOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

check_notifiable_work

Is this work notifiable, and who can do it?

For plumbing and heating jobs in England or Wales: does it need a Gas Safe registered engineer, an unvented (G3) qualified installer, building regulations notification (Approved Documents G, J, L and others) and a water company notice (Water Fittings Regulations, regulation 5)? Returns, per job, who can do it, the self-certification route (competent person scheme within 30 days, or building control before starting) and what to do next, including CO alarm and Boiler Plus rules. Typical call: {"nation":"england","work":["gas_boiler_replacement","unvented_cylinder_new"]}.

ParameterTypeRequiredDescription
nationenum: "england" | "wales"noDefault england.
workarray<enum: "gas_boiler_new" | "gas_boiler_replacement" | "gas_fire_or_appliance" | "gas_cooker" | "gas_pipework" | "gas_service_or_safety_check" | "gas_meter_move" | "oil_boiler_new_or_replacement" …>yesOne or more jobs.
water_approved_contractorbooleannoTrue if the installer is a water approved contractor (for example WaterSafe).
tradeobjectnoOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

check_gas_record

Check a gas safety record or commissioning record before issuing it

Checks a filled landlord gas safety record (CP12) or a boiler commissioning record and lists errors and warnings: missing required fields, failed tightness, flue, ventilation or safety device checks, CO/CO2 ratio over the limits, gas rate off the rated input, meter pressure out of range, an unsafe appliance marked safe, and the correct next due date (keeping the anniversary for checks done up to 2 months early). Gas safety record fields: property_address, landlord_name, landlord_address, engineer_name, gas_safe_registration_number, engineer_licence_number, check_date, previous_record_expiry_date, next_check_due, engineer_signature, tightness_test_passed, emergency_control_accessible, meter_standing_pressure_mbar, meter_working_pressure_mbar, appliances[] {type, make, model, location, flue_type, flue_check_passed, ventilation_satisfactory, safety_devices_ok, co_ppm, co2_percent, co_co2_ratio, rated_heat_input_kw_gross, measured_gas_rate_m3_h, inlet_working_pressure_mbar, status (safe, ncs, at_risk, immediately_dangerous), safe_to_use, action_taken}. Commissioning fields: property_address, engineer_name, commissioning_date, boiler_type, system_flushed, inhibitor_added, inhibitor_name, filter_fitted, water_hardness_ppm, scale_reducer_fitted, condensate_external_pipe_mm, controls_time_and_temperature, combi_extra_measure, co_alarm_fitted, building_regs_notified, dhw_flow_l_min, dhw_temp_rise_c, appliances[] {make, model, serial_number, co_ppm, co2_percent, min_rate {co_ppm, co2_…

ParameterTypeRequiredDescription
record_typeenum: "gas_safety_record" | "commissioning"yes
recordobjectyesThe filled fields (see the description).
tradeobjectnoOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

emergency_triage

Emergency triage for leaks, bursts, no heat, gas smell or CO alarm

For a homeowner reporting a problem: the safe first steps to do now, what not to do, who to call first (the gas emergency service 0800 111 999 for a gas smell or CO alarm), whether it is a real emergency, and an `urgency` value of routine, soon or emergency that matches Nero Work's three job speeds, raised for water near electrics, a bulging ceiling, a vulnerable person in the cold, or water that cannot be stopped. Also returns `nero_work_job` (urgency, category, summary) ready to post. Typical call: {"situation":"no_heat","vulnerable_people":true,"outside_temp_c":2,"other_heating_available":false}.

ParameterTypeRequiredDescription
situationenum: "gas_smell" | "co_alarm" | "co_symptoms" | "burst_pipe" | "leak" | "water_through_ceiling" | "no_heat" | "no_hot_water" …yes
nationenum: "england" | "wales" | "scotland" | "northern_ireland"noChanges the gas emergency number for Northern Ireland.
vulnerable_peoplebooleannoElderly, very young, disabled or medically vulnerable person in the home.
outside_temp_cnumberno
water_near_electricsbooleanno
ceiling_bulgingbooleanno
water_stoppedbooleannoHas turning off the stop tap or valve stopped the water?
pipe_splitbooleanno
other_heating_availablebooleanno
only_toiletbooleanno
sewage_insidebooleanno
tradeobjectnoOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

property_check

Live planning check for a heat pump or flue at a postcode

Looks up, live from official open data, what applies at the customer's postcode before an air source heat pump, a new boiler flue or external pipework: listed buildings, conservation areas, Article 4 directions, World Heritage Sites, National Landscapes, scheduled monuments and flood risk zones (planning.data.gov.uk, England, councils that publish), plus any live Environment Agency flood warnings within 10 km. Returns each constraint found with its source link, whether an air source heat pump is likely permitted development there, what each constraint means for heating and plumbing work, and the council and nation. A constraint not found is not proof of none: the answer says so. Example: {"postcode":"YO1 7HH"}.

ParameterTypeRequiredDescription
postcodestringyesThe job's full UK postcode.

flood_warnings

Live flood warnings near a postcode

Reads the Environment Agency real time flood warning service (England, updated every 15 minutes) for flood alerts, flood warnings and severe flood warnings near the customer's postcode, and says what to tell the customer: flood water or a plumbing fault, whether to send an engineer, Floodline's number. Wales, Scotland and Northern Ireland get the link to their own flood service. Use it before emergency_triage when water is coming in. Example: {"postcode":"YO1 7HH","radius_km":10}.

ParameterTypeRequiredDescription
postcodestringyesThe property's full UK postcode.
radius_kmnumbernoSearch radius, 1 to 50 km. Default 10.

trade_profile

Check the plumber or heating engineer's business details

Checks the business's own details (Nero Trade Profile v1: trading name, Companies House number, registration scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration (licence_body gas_safe plus the Gas Safe registration number) or the company number. The same shape and reference as Spark Pack, so one business keeps one reference across trades. The same object, given as `trade` to the other tools, prefills records. Flow Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.

ParameterTypeRequiredDescription
tradeobjectyesOptional. The plumber or heating engineer's own business details (Nero Trade Profile v1, the same shape as Spark Pack and Nero Work). Used to prefill records and to give a stable nero_trade_ref. Not stored by Flow Pack.

Client compatibility

Based on the transports each client documents as supported; this is not a live test inside the client.

ClientDocumented transportsThis serverSource
Claude Codestdio Streamable HTTP SSEtransport accepteddoc
Claude (claude.ai, Claude Desktop, Cowork)stdio Streamable HTTP SSEtransport accepteddoc
ChatGPT (serveurs MCP personnalisés / plugins)Streamable HTTP SSEtransport accepteddoc
Cursorstdio Streamable HTTP SSEtransport accepteddoc
VS Code (GitHub Copilot)stdio Streamable HTTP SSEtransport accepteddoc
Windsurf (documentation redirigée vers Devin Local / Devin CLI)stdio Streamable HTTP SSEtransport accepteddoc
Gemini CLIstdio Streamable HTTP SSEtransport accepteddoc
OpenAI Codex (CLI, extension IDE, app)stdio Streamable HTTPtransport accepteddoc

Ready-to-copy configs

Remote address used: https://flow-pack.nerolabs.workers.dev/mcp. Formats taken from each client’s documentation.

Claude Code
claude mcp add --transport http flow-pack https://flow-pack.nerolabs.workers.dev/mcp
Claude (claude.ai, Claude Desktop, Cowork)
Customize > Connectors > + Add > Add custom connector ; Name : flow-pack ; URL : https://flow-pack.nerolabs.workers.dev/mcp
ChatGPT (serveurs MCP personnalisés / plugins)
chatgpt.com/plugins > + > Add custom MCP server ; Name : flow-pack ; Server URL : https://flow-pack.nerolabs.workers.dev/mcp ; Create as a plugin
Cursor.cursor/mcp.json (projet) ou ~/.cursor/mcp.json (global)
{
  "mcpServers": {
    "flow-pack": {
      "url": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
VS Code (GitHub Copilot).mcp.json à la racine du workspace, ou ~/.copilot/mcp-config.json ($COPILOT_HOME/mcp-config.json)
{
  "mcpServers": {
    "flow-pack": {
      "type": "http",
      "url": "https://flow-pack.nerolabs.workers.dev/mcp",
      "tools": ["*"]
    }
  }
}
Windsurf (documentation redirigée vers Devin Local / Devin CLI).devin/mcp_config.json (projet), .devin/mcp_config.local.json (local), ~/.config/devin/mcp_config.json (utilisateur)
{
  "mcpServers": {
    "flow-pack": {
      "url": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
Gemini CLI~/.gemini/settings.json (utilisateur) ou .gemini/settings.json (projet)
{
  "mcpServers": {
    "flow-pack": {
      "httpUrl": "https://flow-pack.nerolabs.workers.dev/mcp"
    }
  }
}
OpenAI Codex (CLI, extension IDE, app)~/.codex/config.toml (ou .codex/config.toml pour un projet de confiance)
[mcp_servers.flow-pack]
url = "https://flow-pack.nerolabs.workers.dev/mcp"

Cite this source

Writing an article or comparison? This entry distinguishes registry information from our measurements. Cite the permanent link and the test date; an OK result is not a security audit or an availability guarantee.

Flow Pack · L’Atlas · Tested on

Markdown
[Flow Pack — L’Atlas](https://latlas.dev/en/mcp/io.github.Nero-Engine/flow-pack)
Test methodology and limitations

Source : Registre officiel MCP · retrieved 29 Nov 2026. L’Atlas adds no data beyond this source and its own tests.