L'Atlas / Serveurs MCP / Timberr Framing Tools

Timberr Framing Tools

com.timberrframing/tools

Serveur MCP OK

Faire examiner Voir les tarifs

Planning calculators for structural framing and building projects.

Fiche technique

Auteur
timberrframing.com (espace de noms du registre)
Dépôt
—
Site
—
Version
1.0.0
Transport
Streamable HTTP
Authentification
Aucune (constatée par notre test)
Adresse du serveur
https://timberrframing.com/mcp Streamable HTTP
Outils
15
Catégories
—
Dernière mise à jour
16 nov. 2026
Publication
16 nov. 2026

Badge pour votre README

Référencé sur L’Atlas

Gratuit, pour toute fiche. Il renvoie vers cette fiche et affiche « testé OK » tant que notre dernier test est réussi.

MarkdownREADME.md
[![Référencé sur L’Atlas](https://latlas.dev/badge/fiche/com.timberrframing/tools.svg)](https://latlas.dev/mcp/com.timberrframing/tools)
HTML
<a href="https://latlas.dev/mcp/com.timberrframing/tools"><img src="https://latlas.dev/badge/fiche/com.timberrframing/tools.svg" alt="Référencé sur L’Atlas" height="20"></a>

Nos tests

Chaque semaine : initialize puis tools/list, sans identifiant, sans jamais appeler d’outil. Méthode

Adresse
https://timberrframing.com/mcp
Dernier résultat
OK 28 nov. 2026, 10:25
Temps de réponse
951 ms (initialize + tools/list)
Version du protocole
2025-11-25
Nom annoncé
Timberr Framing 1.0.0
Outils
15

Historique

DateRésultatRéponseOutils
28 nov. 2026, 10:25OK951 ms15

Outils exposés (15, réponse à tools/list, 28 nov. 2026)

wall_framing_calculator

Wall Framing Calculator

Studs, plate length and plate boards for a framed wall from its length, height, stud spacing, openings, corners and intersections. Source: Timberr Framing counting rules (field studs, king and jack studs, cripples, corners, intersections, plates); headers are not sized.

ParamètreTypeRequisDescription
length_ftnumberouiWall length, feet (or use length_m). Add length_in for extra inches. Unit: ft.
length_innumbernonExtra inches added to length_ft. Unit: in.
length_mnumbernonWall length in metres, instead of length_ft. Unit: m.
height_ftnumbernonWall height, feet. Unit: ft.
spacing_inenum: 12 | 16 | 24nonStud spacing on centre. Unit: in.
top_platesenum: 1 | 2nonTop plate courses.
cornersintegernonNumber of corners (2 studs each).
intersectionsintegernonPlaces another wall meets this wall (2 studs each).
waste_pctnumbernonWaste allowance, 0 to 50. Unit: %.
openingsstringnonComma separated type:rough-opening-width-in-inches, for example door:36,window:48.

floor_joist_span_calculator

Floor Joist Span Calculator

Maximum floor joist span for dimension lumber from Table 9.23.4.2.-A of the 2024 Ontario Building Code, and whether your clear span is within it. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-A, Maximum Spans for Floor Joists, General Cases.

ParamètreTypeRequisDescription
speciesenum: "SPF" | "DFL" | "Hem-Fir" | "Northern"nonSpecies group.
gradeenum: "SS" | "No1" | "No3"nonLumber grade.
sizeenum: "2x4" | "2x6" | "2x8" | "2x10" | "2x12"nonJoist or rafter size (38 mm thick).
spacing_mmenum: 300 | 400 | 600nonSpacing on centre (12, 16 and 24 in are also accepted). Unit: mm.
supportenum: "strapping" | "bridging" | "both"nonBridging and strapping.
span_ftnumberouiClear span between the inside faces of the supports in feet (or use span_m). Unit: ft.
span_innumbernonExtra inches added to span_ft. Unit: in.
span_mnumbernonClear span between the inside faces of the supports in metres, instead of span_ft. Unit: m.

roof_rafter_span_calculator

Roof Rafter Span Calculator

Maximum horizontal span of a wood roof rafter from Table 9.23.4.2.-F of the 2024 Ontario Building Code for specified roof snow loads of 1.0 to 2.0 kPa. Source: Ontario Building Code 2024, Division B, Table 9.23.4.2.-F, Maximum Spans for Roof Rafters, Specified Roof Snow Loads 1.0 to 2.0 kPa.

ParamètreTypeRequisDescription
speciesenum: "SPF" | "DFL" | "Hem-Fir" | "Northern"nonSpecies group.
gradeenum: "SS" | "No1" | "No3"nonLumber grade.
sizeenum: "2x4" | "2x6" | "2x8" | "2x10" | "2x12"nonRafter size (38 mm thick).
spacing_mmenum: 300 | 400 | 600nonSpacing on centre (12, 16 and 24 in are also accepted). Unit: mm.
snow_kpaenum: 1 | 1.5 | 2nonSpecified roof snow load; the column at or above it is used. Unit: kPa.
span_ftnumberouiHorizontal span between the inside faces of the supports in feet (or use span_m). Unit: ft.
span_innumbernonExtra inches added to span_ft. Unit: in.
span_mnumbernonHorizontal span between the inside faces of the supports in metres, instead of span_ft. Unit: m.

lintel_size_lookup

Lintel and Header Size Lookup

Smallest sawn lumber lintel over a door or window opening in a loadbearing wall, from Tables 9.23.12.3.-A to C of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Tables 9.23.12.3.-A to 9.23.12.3.-C, Maximum Spans for Lintels (No. 1 or No. 2 grade lumber).

ParamètreTypeRequisDescription
speciesenum: "SPF" | "DFL" | "Hem-Fir"nonLumber species group (No. 1 or No. 2 grade).
supportsenum: "attic" | "roof" | "roof-wide" | "1-storey" | "2-storey" | "3-storey"nonWhat the lintel supports: attic (limited attic storage and ceiling), roof (roof and ceiling, tributary width 0.6 m max), roof-wide (roof and ceiling, 4.9 m max), 1-storey, 2-storey, 3-storey (roof, ceiling and that many storeys). The numbers 0 to 5 are also accepted.
wallenum: "exterior" | "interior"nonExterior or interior wall (attic is always interior).
snow_kpaenum: 1 | 1.5 | 2 | 2.5 | 3nonSpecified roof snow load for exterior walls; the column at or above it is used. Unit: kPa.
opening_ftnumberouiOpening width in feet (or use opening_m). Unit: ft.
opening_innumbernonExtra inches added to opening_ft. Unit: in.
opening_mnumbernonOpening width in metres, instead of opening_ft. Unit: m.
floor_joists_full_widthenum: "no" | "yes"nonFloor joists span the full building width without support (table note 3 reduction for 1 to 3 storeys).

stair_stringer_calculator

Stair Stringer Calculator

Riser count and height, treads, total run and stringer length for a straight private stair, checked against Table 9.8.4.1. of the 2024 Ontario Building Code. Source: Ontario Building Code 2024, Division B, Part 9, Table 9.8.4.1. and Articles 9.8.3.3. and 9.8.4.2.

ParamètreTypeRequisDescription
rise_mmnumbernonTotal rise, finished floor to finished floor, in millimetres (or use rise_ft and rise_in). Unit: mm.
rise_ftnumbernonTotal rise feet, instead of rise_mm. Unit: ft.
rise_innumbernonTotal rise extra inches, added to rise_ft. Unit: in.
run_mmnumbernonRun per tread, 255 to 355 mm. Unit: mm.
nosing_mmnumbernonTread nosing projection. Unit: mm.
thickness_mmnumbernonTread thickness. Unit: mm.

roof_pitch_rafter_length_calculator

Roof Pitch and Rafter Length Calculator

Common rafter length, roof angle, slope factor and plumb cut from the roof pitch, building span, overhang and ridge board thickness. Source: Roof geometry (Pythagorean slope factor); no code table involved.

ParamètreTypeRequisDescription
pitchnumberouiRoof pitch, inches of rise per 12 inches of run.
span_ftnumberouiBuilding span, outside of plate to outside of plate, feet. Unit: ft.
span_innumbernonExtra inches added to span_ft. Unit: in.
overhang_innumbernonHorizontal overhang past the plate. Unit: in.
ridge_innumbernonRidge board thickness. Unit: in.

sheathing_sheet_calculator

Sheathing and Subfloor Sheet Calculator

Sheets of plywood or OSB needed to cover a floor, wall or sloped roof from its size, roof pitch, openings and waste allowance. Source: Area arithmetic (slope factor for roofs); no code table involved.

ParamètreTypeRequisDescription
surfaceenum: "floor" | "wall" | "roof"nonSurface to cover.
sheetenum: "4x8" | "4x9" | "4x10"nonSheet size, feet.
length_ftnumberouiLength in feet (wall length for a wall). Unit: ft.
width_ftnumberouiWidth in feet (wall height for a wall, plan width eave to eave for a roof). Unit: ft.
pitchnumbernonRoof pitch, rise per 12 (roof only).
openings_sqftnumbernonOpenings to subtract. Unit: sq ft.
waste_pctnumbernonWaste allowance, 0 to 50. Unit: %.

window_and_door_rough_opening_planner

Window and Door Rough Opening Schedule

Rough opening width and height for a list of windows and doors from the unit sizes and the side, top and sill gaps you enter, one printable row per opening. Source: Arithmetic on the unit size and gaps you enter; the manufacturer rough opening table for each unit governs.

ParamètreTypeRequisDescription
linesstringouiComma separated label:unit_width_in:unit_height_in:gap_each_side_in:gap_top_in:gap_sill_in:quantity, for example W1:36:48:0.5:0.5:0.75:2,D1:36:80:0.5:0.5:0.5:1. Sizes and gaps are in inches. No gap is assumed; take each from the unit installation instructions.

lumber_board_foot_calculator

Lumber Takeoff and Board Foot Calculator

Board feet, linear feet and piece counts for a list of dimension lumber sizes, lengths and quantities, with a waste allowance. Source: Board foot arithmetic on nominal size: thickness in x width in x length ft / 12; no code table involved.

ParamètreTypeRequisDescription
linesstringouiComma separated size:length_ft:quantity, for example 2x4:8:100,2x6:12:20. Sizes: 2x4, 2x6, 2x8, 2x10, 2x12, 4x4, 4x6, 6x6.
waste_pctnumbernonWaste allowance, 0 to 50. Unit: %.

nailing_schedule_lookup

Framing Nailing Schedule Lookup

Minimum nail length and number or spacing of nails for framing connections, from Table 9.23.3.4. of the 2024 Ontario Building Code. Filter by part of the frame and search words. Source: Ontario Building Code 2024, Division B, Table 9.23.3.4., Nailing for Framing.

ParamètreTypeRequisDescription
groupenum: "Floor and joist framing" | "Wall framing" | "Roof framing" | "Plank decking"nonPart of the frame (omit for all).
qstringnonSearch words in the connection description, for example stud, rafter, plate, joist.

deck_joist_and_beam_span_calculator

Deck Joist and Beam Span Calculator

Maximum deck joist span from Table 9.23.4.2.-A, the smallest built-up lumber beam from Table 9.23.4.2.-H for your post spacing, and the minimum post size from Article 9.17.4.1. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-A and 9.23.4.2.-H, Articles 9.4.2.3., 9.4.2.2., 9.17.1.1. and 9.17.4.1., and SB-1 Table 2.

ParamètreTypeRequisDescription
speciesenum: "SPF" | "DFL" | "Hem-Fir" | "Northern"nonSpecies group.
gradeenum: "SS" | "No1" | "No3"nonLumber grade.
sizeenum: "2x4" | "2x6" | "2x8" | "2x10" | "2x12"nonJoist or rafter size (38 mm thick).
spacing_mmenum: 300 | 400 | 600nonSpacing on centre (12, 16 and 24 in are also accepted). Unit: mm.
supportenum: "strapping" | "bridging" | "both"nonJoist bridging and strapping (Table 9.23.4.2.-A).
span_ftnumberouiJoist clear span in feet (or use span_m). With a ledger on the house this is the distance from the ledger to the beam. Unit: ft.
span_innumbernonExtra inches added to span_ft. Unit: in.
span_mnumbernonJoist clear span between the ledger or beam on each side in metres, instead of span_ft. Unit: m.
other_side_span_ftnumbernonJoist span on the far side of the beam, for a beam in the middle of the deck. Leave 0 for a beam at the edge. Unit: ft.
post_spacing_ftnumberouiClear span of the beam between posts, in feet (or use post_spacing_m). Unit: ft.
post_spacing_mnumbernonBeam span between posts in metres, instead of post_spacing_ft. Unit: m.
cityenum: "toronto" | "etobicoke" | "north-york" | "scarborough" | "mississauga" | "brampton" | "vaughan" | "markham" …nonOntario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead.
ss_kpanumbernonGround snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa.
sr_kpanumbernonRain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa.

load_bearing_wall_removal_beam_sizer_guide

Load-Bearing Wall Removal Beam Guide

Checks whether removing a load-bearing wall can stay inside the Ontario Building Code Part 9 beam tables, flags when an engineer is needed, and lists the published beam size ranges from Tables 9.23.4.2.-H to -L and 9.23.4.3.-A to -J. It is not a design. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-H to -L, 9.23.4.3. and 9.23.4.3.-A to -J, Articles 9.4.1.1. and 9.23.4.1., Note A-9.23.4.2.; Building Code Act, 1992, ss. 1(1) and 8(1).

ParamètreTypeRequisDescription
opening_ftnumberouiWidth of the opening the beam must cross, in feet (or use opening_m). Add opening_in for extra inches. Unit: ft.
opening_innumbernonExtra inches added to opening_ft. Unit: in.
opening_mnumbernonOpening width in metres, instead of opening_ft. Unit: m.
floors_aboveenum: 0 | 1 | 2 | 3nonNumber of floors bearing on the wall, not counting the roof.
roof_aboveenum: "yes" | "no"nonDoes roof framing (rafters, joists or trusses) bear on this wall?
wallenum: "siding" | "brick"nonWall above the beam: exterior with brick veneer, or interior or exterior with siding (affects the steel tables only).
floor_supported_ftnumbernonSupported floor joist length: half the sum of the joist spans on both sides of the beam, in feet. Unit: ft.
roof_supported_ftnumbernonSupported roof length: half the sum of rafter, joist or truss spans on both sides, in feet. Unit: ft.
cityenum: "toronto" | "etobicoke" | "north-york" | "scarborough" | "mississauga" | "brampton" | "vaughan" | "markham" …nonOntario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead.
ss_kpanumbernonGround snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa.
sr_kpanumbernonRain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa.
point_loadsenum: "yes" | "no"nonDoes a post, a girder truss, a stair or another beam land on the beam as a point load?
trusses_bearenum: "yes" | "no"nonDo roof trusses bear on the wall being removed?

truss_vs_rafter_span_checker

Truss vs Rafter Span Checker

Reads the specified roof snow load for an Ontario city from SB-1 and Article 9.4.2.2., then checks whether a site-built rafter in Tables 9.23.4.2.-F and -G of the 2024 Ontario Building Code can span your roof or whether roof trusses are needed. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Tables 9.23.4.2.-F and 9.23.4.2.-G, Articles 9.4.2.1., 9.4.2.2. and 9.23.14.11.; SB-1 Table 2 (Ss and Sr).

ParamètreTypeRequisDescription
speciesenum: "SPF" | "DFL" | "Hem-Fir" | "Northern"nonSpecies group.
gradeenum: "SS" | "No1" | "No3"nonLumber grade.
spacing_mmenum: 300 | 400 | 600nonRafter spacing on centre (12, 16 and 24 in are also accepted). Unit: mm.
span_ftnumberouiHorizontal span between the inside faces of the supports, in feet (or use span_m). Unit: ft.
span_innumbernonExtra inches added to span_ft. Unit: in.
span_mnumbernonHorizontal span in metres, instead of span_ft. Unit: m.
pitchnumbernonRoof pitch as rise per 12 of run, used only to report the sloped rafter length.
narrow_roofenum: "yes" | "no"nonIs the entire roof width 4.3 m or less? (Article 9.4.2.2.: basic roof factor Cb 0.45 instead of 0.55.)
cityenum: "toronto" | "etobicoke" | "north-york" | "scarborough" | "mississauga" | "brampton" | "vaughan" | "markham" …nonOntario city, to read the 1-in-50 year ground snow load Ss and rain load Sr from SB-1 Table 2. Leave empty and give ss_kpa and sr_kpa instead.
ss_kpanumbernonGround snow load Ss from SB-1 Table 2, used when city is empty. Unit: kPa.
sr_kpanumbernonRain load Sr from SB-1 Table 2, used when city is empty. Unit: kPa.

firewall_and_party_wall_fire_rating_checker

Firewall and Party Wall Fire Rating Checker

Fire-resistance rating and sound rating the 2024 Ontario Building Code Part 9 requires for a wall between dwelling units: a party wall on a property line (townhouse, semi-detached), a wall between suites in one building, a house with a secondary suite, or a garage wall. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.10.8.1., 9.10.9.15., 9.10.9.16., 9.10.9.18., 9.10.11.1. to 9.10.11.4., 9.11.1.1. and 9.11.1.3., and Article 3.1.10.2. to 3.1.10.5.

ParamètreTypeRequisDescription
wall_useenum: "party-wall" | "suites" | "secondary-suite" | "garage-garage" | "garage-dwelling"nonWhat the wall separates: party-wall (dwelling units on either side of a property line, such as townhouses or semi-detached houses), suites (units in one building with no property line, such as a duplex, triplex or stacked units), secondary-suite (a house with a secondary suite), garage-garage (two…
unit_above_unitenum: "yes" | "no"nonIs any dwelling unit above another dwelling unit (stacked units)?
two_storey_unitenum: "yes" | "no"nonDoes a dwelling unit have 2 or more storeys, counting the basement?
sprinkleredenum: "yes" | "no"nonIs the house with a secondary suite sprinklered? Used for the secondary-suite case only.
garage_serves_dwellingenum: "yes" | "no"nonDoes the garage serve only the dwelling it is attached to? Used for garage-dwelling only.

post_and_footing_size_calculator

Post and Footing Size Calculator

Minimum footing area and thickness for a post or column from Table 9.15.3.4. (house) or from the 2.4 kPa deck load over 75 kPa soil, the minimum post size from Article 9.17.4.1., and the minimum foundation depth from Table 9.12.2.2. of the 2024 Ontario Building Code. Source: 2024 Ontario Building Code (O. Reg. 163/24), Division B, Articles 9.15.1.1., 9.15.3.3. to 9.15.3.8., 9.4.2.3., 9.4.4.1. (Table 9.4.4.1.), 9.12.2.2. (Table 9.12.2.2.) and 9.17.1.1. to 9.17.4.1.

ParamètreTypeRequisDescription
kindenum: "house" | "deck"nonhouse (interior column or post under a beam in a building) or deck (post under a deck or porch beam).
floorsenum: 1 | 2 | 3nonHouse only: number of floors the column supports.
column_spacing_ftnumbernonHouse only: spacing of the columns along the beam, in feet. The table is for 3 m (9.8 ft) and the area is adjusted in proportion (Article 9.15.3.7.). Unit: ft.
joist_span_ftnumbernonSupported joist length, in feet: half the sum of the joist spans on both sides of the beam. House: at most 16 ft (4.9 m). Unit: ft.
beam_span_ftnumbernonDeck only: supported beam length, half the sum of the beam spans on both sides of the post, in feet. At most 10 ft. Unit: ft.
soilenum: "rock" | "till" | "dense-sand-gravel" | "dense-silt" | "stiff-clay" | "firm-clay" | "loose-sand-gravel" | "soft-clay" …nonSoil or rock at the footing (Table 9.4.4.1.).
high_water_tableenum: "yes" | "no"nonIs the water table less than the footing width below the bearing surface? It doubles the footing area on gravel, sand or silt (Article 9.15.3.4.(3)).
heatedenum: "yes" | "no"nonDoes the foundation contain a heated space (house)? Decks, porches and unheated space: no.
drainageenum: "good" | "poor"nonSoil drainage to at least the depth of frost penetration.
deck_area_m2numbernonDeck only: deck area in square metres, for the floating deck check in Sentence 9.12.2.2.(7). Unit: m2.
height_mmnumbernonDeck only: distance from ground to the underside of the joists, in millimetres. Unit: mm.
attachedenum: "yes" | "no"nonDeck only: is the deck attached to a house or another structure?
roof_overenum: "yes" | "no"nonDeck only: does the deck support a roof?

Compatibilité clients

Selon les transports que chaque client déclare accepter dans sa documentation officielle ; ce n’est pas un essai réel dans le client.

ClientTransports documentésCe serveurSource
Claude Codestdio Streamable HTTP SSEtransport acceptédoc
Claude (claude.ai, Claude Desktop, Cowork)stdio Streamable HTTP SSEtransport acceptédoc
ChatGPT (serveurs MCP personnalisés / plugins)Streamable HTTP SSEtransport acceptédoc
Cursorstdio Streamable HTTP SSEtransport acceptédoc
VS Code (GitHub Copilot)stdio Streamable HTTP SSEtransport acceptédoc
Windsurf (documentation redirigée vers Devin Local / Devin CLI)stdio Streamable HTTP SSEtransport acceptédoc
Gemini CLIstdio Streamable HTTP SSEtransport acceptédoc
OpenAI Codex (CLI, extension IDE, app)stdio Streamable HTTPtransport acceptédoc

Configs prêtes à copier

Adresse distante utilisée : https://timberrframing.com/mcp. Formats repris de la documentation de chaque client.

Claude Code
claude mcp add --transport http tools https://timberrframing.com/mcp
Claude (claude.ai, Claude Desktop, Cowork)
Customize > Connectors > + Add > Add custom connector ; Name : tools ; URL : https://timberrframing.com/mcp
ChatGPT (serveurs MCP personnalisés / plugins)
chatgpt.com/plugins > + > Add custom MCP server ; Name : tools ; Server URL : https://timberrframing.com/mcp ; Create as a plugin
Cursor.cursor/mcp.json (projet) ou ~/.cursor/mcp.json (global)
{
  "mcpServers": {
    "tools": {
      "url": "https://timberrframing.com/mcp"
    }
  }
}
VS Code (GitHub Copilot).mcp.json à la racine du workspace, ou ~/.copilot/mcp-config.json ($COPILOT_HOME/mcp-config.json)
{
  "mcpServers": {
    "tools": {
      "type": "http",
      "url": "https://timberrframing.com/mcp",
      "tools": ["*"]
    }
  }
}
Windsurf (documentation redirigée vers Devin Local / Devin CLI).devin/mcp_config.json (projet), .devin/mcp_config.local.json (local), ~/.config/devin/mcp_config.json (utilisateur)
{
  "mcpServers": {
    "tools": {
      "url": "https://timberrframing.com/mcp"
    }
  }
}
Gemini CLI~/.gemini/settings.json (utilisateur) ou .gemini/settings.json (projet)
{
  "mcpServers": {
    "tools": {
      "httpUrl": "https://timberrframing.com/mcp"
    }
  }
}
OpenAI Codex (CLI, extension IDE, app)~/.codex/config.toml (ou .codex/config.toml pour un projet de confiance)
[mcp_servers.tools]
url = "https://timberrframing.com/mcp"

Citer cette source

Vous rédigez un article ou un comparatif ? Cette fiche distingue les informations du registre et nos mesures. Citez le lien permanent et la date du test ; un résultat OK ne constitue pas un audit de sécurité ni une garantie de disponibilité.

Timberr Framing Tools · L’Atlas · Test du

Markdown
[Timberr Framing Tools — L’Atlas](https://latlas.dev/mcp/com.timberrframing/tools)
Méthode et limites des tests

Source : Registre officiel MCP · relevé le 29 nov. 2026. L’Atlas n’ajoute aucune donnée qui ne vienne de cette source ou de ses propres tests.