Spark Pack
io.github.Nero-Engine/spark-pack
Serveur MCP OK 8 outils
Live listed building and conservation area checks, cable sizing, Part P and G98/G99 for electricians
Fiche technique
- Auteur
- Nero-Engine (espace de noms du registre)
- Dépôt
- github.com/Nero-Engine/spark-pack-mcp
- Site
- spark-pack.nerolabs.workers.dev/docs
- Version
- 1.2.0
- Transport
- Streamable HTTP
- Authentification
- Aucune (constatée par notre test)
- Adresse du serveur
- https://spark-pack.nerolabs.workers.dev/mcp Streamable HTTP
- Outils
- 8
- Catégories
- —
- Dernière mise à jour
- 27 nov. 2026
- Publication
- 27 nov. 2026
Badge pour votre README
Gratuit, pour toute fiche. Il renvoie vers cette fiche et affiche « testé OK » tant que notre dernier test est réussi.
[](https://latlas.dev/mcp/io.github.Nero-Engine/spark-pack)<a href="https://latlas.dev/mcp/io.github.Nero-Engine/spark-pack"><img src="https://latlas.dev/badge/fiche/io.github.Nero-Engine/spark-pack.svg" alt="Référencé sur L’Atlas" height="20"></a>Nos tests
Chaque semaine : initialize puis tools/list, sans identifiant, sans jamais appeler d’outil. Méthode
- Adresse
- https://spark-pack.nerolabs.workers.dev/mcp
- Dernier résultat
- OK 28 nov. 2026, 09:44
- Temps de réponse
- 588 ms (initialize + tools/list)
- Version du protocole
- 2025-06-18
- Nom annoncé
- nerolabs-spark-pack 1.2.0
- Outils
- 8
Historique
| Date | Résultat | Réponse | Outils |
|---|---|---|---|
| 28 nov. 2026, 09:44 | OK | 588 ms | 8 |
Outils exposés (8, réponse à tools/list, 28 nov. 2026)
list_capabilities
What Spark Pack can do
Lists Spark Pack's tools, the regulations edition it targets, what it covers (nations, circuit types, cable types, installation methods) and what it deliberately does not do. Free, needs no input.
Aucun paramètre.
size_cable
Cable size, voltage drop and earth fault loop check
Sizes a UK final circuit or sub-main and shows the working: design current (with cooker diversity), protective device rating, the smallest cable size that passes current-carrying capacity, voltage drop (3% lighting, 5% other) and earth fault loop impedance (Zs against the maximum for B, C or D breakers), plus a cpc adiabatic check. Returns `recommended` (size and every check with status pass, fail, indicative_pass, needs_input), `sizes_considered` (one line per size), `must_check_against_regs` (points the electrician confirms in BS 7671) and sources. Current-carrying capacity comes from a cautious heat-flow model, not BS 7671 tables, so it is marked indicative; give `cable_size_mm2` plus `tabulated_capacity_a` from the regs for a firm check. Voltage drop and Zs are calculated from physics and are firm for the inputs given. Typical call: a 9.5 kW shower on an 18 m run clipped direct: {"circuit_type":"shower","load_kw":9.5,"run_length_m":18,"installation_method":"clipped_direct"}.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| circuit_type | enum: "shower" | "cooker" | "ev_charger" | "ring_final" | "radial_sockets" | "lighting" | "immersion" | "heat_pump" … | oui | What the circuit feeds. ring_final and radial_sockets can be sized without a load (the device rating is used). |
| load_kw | number | non | Load in kW (for example 9.5 for a shower, 7.4 for a 32 A EV charger). Give this or design_current_a. |
| design_current_a | number | non | Design current Ib in amps, if already known. Overrides load_kw. |
| run_length_m | number | oui | Cable length from the board to the furthest point, metres. For a ring, the total ring length. |
| installation_method | enum: "clipped_direct" | "in_conduit_or_trunking_on_wall" | "in_conduit_in_insulated_wall" | "touching_insulation_one_side" | "surrounded_by_insulation" | "above_ceiling_insulation_under_100mm" | "buried_direct" | "in_duct_underground" | oui | How the cable is run. clipped_direct: Clipped direct to a wall or surface, in free air; in_conduit_or_trunking_on_wall: In conduit or trunking fixed on a wall; in_conduit_in_insulated_wall: In conduit in a thermally insulated wall; touching_insulation_one_side: In a stud wall or ceiling void, touch… |
| cable_type | enum: "twin_and_earth" | "swa_xlpe" | "swa_pvc" | "singles_in_conduit" | non | Defaults to twin_and_earth, or swa_xlpe for buried runs and sub-mains. |
| phases | enum: 1 | 3 | non | Defaults to 1. |
| power_factor | number | non | Defaults to 1 (resistive loads, EV chargers). Use about 0.95 for heat pumps or mixed sub-main loads. |
| protective_device | object | non | The breaker or fuse. Leave rating_a out to let Spark Pack choose the smallest standard rating at or above the design current. |
| cable_size_mm2 | number | non | Check this specific size as well as finding the smallest that passes. |
| tabulated_capacity_a | number | non | Tabulated current-carrying capacity It for cable_size_mm2 and this method, read from BS 7671 Appendix 4 by the electrician. Makes the capacity check firm. |
| ambient_c | number | non | Ambient temperature, C. Defaults to 30 in air, 20 in the ground. |
| grouped_circuits | number | non | Number of circuits bunched together along the run, including this one. Defaults to 1. |
| grouping_factor | number | non | Grouping factor Cg from the regs for the arrangement, if known. Without it Spark Pack uses a cautious estimate. |
| earthing | enum: "tn_c_s" | "tn_s" | "tt" | non | Supply earthing. Defaults to tn_c_s (PME). |
| ze_ohms | number | non | Measured external earth fault loop impedance Ze, ohms. Without it the typical network maximum is used (0.35 TN-C-S, 0.8 TN-S). |
| upstream_voltage_drop_percent | number | non | Voltage drop already used upstream (for a circuit fed from a sub-board), percent. |
| cores | enum: 2 | 3 | 4 | non | SWA only: number of cores. Defaults to 3 single phase (spare core as cpc) or 4 three phase. With 2 the armour is the cpc: give armour_resistance_mohm_per_m. |
| cpc_size_mm2 | number | non | Override the circuit protective conductor size (twin and earth sizes are known). |
| armour_resistance_mohm_per_m | number | non | SWA armour resistance from the cable datasheet, milliohms per metre, when the armour is the cpc. |
| soil_thermal_resistivity | number | non | Buried runs: soil thermal resistivity K.m/W, defaults to 2.5 (cautious). |
| apply_cooker_diversity | boolean | non | Cooker only: apply the usual domestic cooker diversity (default true). |
| cooker_has_socket | boolean | non | Cooker only: the cooker control unit has a socket outlet. |
| trade | object | non | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. |
check_part_p
Is this job notifiable under Part P?
Answers whether domestic electrical work in England or Wales must be notified to building control under Part P of the Building Regulations, with the reason and what to do next (self-certify through a competent person scheme within 30 days, or tell building control before starting). England and Wales differ: in Wales kitchens and outdoor areas are still special locations. Returns `notifiable` (true or false), `answer`, `reason`, `what_to_do`, `must_check` and sources. Scotland and Northern Ireland return not_covered. Example: adding a socket in a kitchen in England: {"nation":"england","work":"add_to_or_alter_existing_circuit","locations":["kitchen"]}.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| nation | enum: "england" | "wales" | "scotland" | "northern_ireland" | oui | Where the property is. |
| work | enum: "new_circuit" | "consumer_unit_replacement" | "add_to_or_alter_existing_circuit" | "replace_like_for_like" | "repair_or_maintenance" | "connect_equipment_to_existing_point" | oui | The kind of work. Pick the most significant if the job has several parts (a new circuit outranks everything). |
| locations | array<enum: "bath_or_shower_zone" | "swimming_or_paddling_pool" | "sauna_heater_room" | "kitchen" | "outdoors" | "elsewhere"> | non | Where the work is. bath_or_shower_zone means within the zoned space around a bath or shower. Defaults to ["elsewhere"]. |
| building | enum: "dwelling" | "outbuilding_or_garden_of_dwelling" | "common_parts_of_flats" | "commercial_or_industrial" | non | Defaults to dwelling. |
| registered_with_competent_person_scheme | boolean | non | Whether the electrician is registered with a scheme such as NICEIC or NAPIT. Changes the next steps. |
| trade | object | non | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. |
get_certificate_schema
Certificate fields as a JSON schema
Returns the fields an Electrical Installation Certificate (eic), Minor Electrical Installation Works Certificate (minor_works) or Electrical Installation Condition Report (eicr) needs, as a JSON Schema the assistant fills from the job notes and test readings (spark-pack-certs-1.0 (for BS 7671:2018+A4:2026 certificates)). Includes which certificate to use when, and the contractor block prefilled from `trade` if given. check_certificate checks the filled object. Field names are Spark Pack's own; the electrician transfers the values to the official form in their scheme portal or software.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| certificate | enum: "eic" | "minor_works" | "eicr" | oui | eic for new circuits, consumer units and new installations; minor_works for additions or alterations to one existing circuit; eicr for periodic inspection reports. |
| trade | object | non | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. |
check_certificate
Check a filled certificate
Checks a filled EIC, Minor Works certificate or EICR (shape from get_certificate_schema) and returns `ready_to_transfer`, every missing required field by path, errors (readings that fail: insulation resistance under 1 megohm at 500 V, measured Zs above the maximum for the breaker, RCD trip times too slow, wrong polarity, an EICR marked satisfactory with a C1 or C2) and warnings (Zs above 80% of maximum, mismatched ring readings, low insulation resistance). Contractor fields left blank are filled from `trade`. Returns the (prefilled) data back.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| certificate | enum: "eic" | "minor_works" | "eicr" | oui | |
| data | object | oui | The certificate object, shaped like the JSON Schema from get_certificate_schema. |
| trade | object | non | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. |
check_grid_connection
G98, G99 or EV and heat pump notification?
For solar PV, batteries, V2G chargers, EV chargers and heat pumps in Great Britain: says which network operator process applies and when. Generation: G98 (fully type tested, 16 A / 3.68 kW per phase or less: install, then notify within 28 days) or G99 (apply and wait for acceptance before installing), counting existing generation and battery inverters. Demand: the ENA EV charge point and heat pump form (connect and notify within 28 days if every criterion is met, otherwise apply first), with each criterion marked true, false or null (not yet known). Returns `generation`, `demand`, `facts_to_put_on_the_form` (prefilled from inputs and `trade`), `missing_facts` and sources. Example: 5 kW solar plus a 5 kW battery inverter on single phase: {"supply_phases":1,"new_equipment":[{"type":"solar_pv","rating_kw":5,"type_tested":true},{"type":"battery","rating_kw":5,"type_tested":true}]}.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| new_equipment | array<object> | oui | Equipment being installed. |
| existing_equipment | array<object> | non | Generation, storage or chargers already at the premises, same shape as new_equipment. |
| supply_phases | enum: 1 | 3 | non | Defaults to 1. |
| export_limit_kw | number | non | Export limit if an export limiting scheme (G100) is fitted. |
| battery_storage_kwh | number | non | |
| max_demand_after_a | number | non | Premises maximum demand after the installation, amps per phase (from a load survey). |
| cut_out_rating_a | number | non | Network cut-out fuse rating, amps. Do not open the cut-out to find it. |
| looped_service | boolean | non | The supply is looped with a neighbour. |
| ct_metered | boolean | non | |
| load_limiting_device | boolean | non | A load limiting or curtailment device keeps demand below the cut-out rating. |
| service_equipment_ok | boolean | non | No safety or adequacy concerns with the cut-out and service cable. |
| metered | boolean | non | The supply is metered (defaults to unknown). |
| heat_pump_single_controller | boolean | non | |
| multiple_premises | boolean | non | Part of several installations in a close area (housing development, street-wide scheme). |
| nation | enum: "great_britain" | "northern_ireland" | non | Defaults to great_britain. |
| site_postcode | string | non | |
| mpan | string | non | Meter point administration number (the supply number on the bill). |
| earthing | string | non | Supply earthing, for example TN-C-S. |
| commissioning_date | string | non | YYYY-MM-DD. |
| trade | object | non | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. |
property_check
Live planning constraints for an electrical job postcode
Looks up, live from official open data, what applies at the customer's postcode before solar PV, battery, EV charger, external cabling, rewire or consumer unit work: listed buildings, conservation areas, Article 4 directions, World Heritage Sites, National Landscapes, scheduled monuments and flood risk zones (planning.data.gov.uk, England, councils that publish). Returns each constraint found with its source link, what it means for the electrical work (listed building consent, solar on a wall facing a road, flood resilient wiring), the council and nation, and the matching check_part_p nation. A constraint not found is not proof of none: the answer says so. Example: {"postcode":"BA1 2LR"}.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| postcode | string | oui | The job's full UK postcode. |
trade_profile
Check the electrician's business details
Checks the electrician's own business details (Nero Trade Profile v1: trading name, Companies House number, competent person scheme and number, postcode, contact) and returns them cleaned, with a stable `nero_trade_ref` computed from the scheme registration or company number. The same object, given as `trade` to the other tools, prefills certificates and grid forms. Spark Pack stores nothing. The same profile and reference can later be used to sign the business into Nero Work, the agent job exchange for trades.
| Paramètre | Type | Requis | Description |
|---|---|---|---|
| trade | object | oui | Optional. The electrician's own business details (Nero Trade Profile v1). Used to prefill certificate contractor fields and to give a stable nero_trade_ref. Not stored by Spark Pack. |
Compatibilité clients
Selon les transports que chaque client déclare accepter dans sa documentation officielle ; ce n’est pas un essai réel dans le client.
| Client | Transports documentés | Ce serveur | Source |
|---|---|---|---|
| Claude Code | stdio Streamable HTTP SSE | transport accepté | doc |
| Claude (claude.ai, Claude Desktop, Cowork) | stdio Streamable HTTP SSE | transport accepté | doc |
| ChatGPT (serveurs MCP personnalisés / plugins) | Streamable HTTP SSE | transport accepté | doc |
| Cursor | stdio Streamable HTTP SSE | transport accepté | doc |
| VS Code (GitHub Copilot) | stdio Streamable HTTP SSE | transport accepté | doc |
| Windsurf (documentation redirigée vers Devin Local / Devin CLI) | stdio Streamable HTTP SSE | transport accepté | doc |
| Gemini CLI | stdio Streamable HTTP SSE | transport accepté | doc |
| OpenAI Codex (CLI, extension IDE, app) | stdio Streamable HTTP | transport accepté | doc |
Configs prêtes à copier
Adresse distante utilisée : https://spark-pack.nerolabs.workers.dev/mcp. Formats repris de la documentation de chaque client.
claude mcp add --transport http spark-pack https://spark-pack.nerolabs.workers.dev/mcpCustomize > Connectors > + Add > Add custom connector ; Name : spark-pack ; URL : https://spark-pack.nerolabs.workers.dev/mcpchatgpt.com/plugins > + > Add custom MCP server ; Name : spark-pack ; Server URL : https://spark-pack.nerolabs.workers.dev/mcp ; Create as a plugin{
"mcpServers": {
"spark-pack": {
"url": "https://spark-pack.nerolabs.workers.dev/mcp"
}
}
}{
"mcpServers": {
"spark-pack": {
"type": "http",
"url": "https://spark-pack.nerolabs.workers.dev/mcp",
"tools": ["*"]
}
}
}{
"mcpServers": {
"spark-pack": {
"url": "https://spark-pack.nerolabs.workers.dev/mcp"
}
}
}{
"mcpServers": {
"spark-pack": {
"httpUrl": "https://spark-pack.nerolabs.workers.dev/mcp"
}
}
}[mcp_servers.spark-pack]
url = "https://spark-pack.nerolabs.workers.dev/mcp"Citer cette source
Vous rédigez un article ou un comparatif ? Cette fiche distingue les informations du registre et nos mesures. Citez le lien permanent et la date du test ; un résultat OK ne constitue pas un audit de sécurité ni une garantie de disponibilité.
Spark Pack · L’Atlas · Test du