L'Atlas / MCP servers / The Cable Code

The Cable Code

io.github.exquad/thecablecode

MCP server OK

Get a review See pricing

Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.

Technical sheet

Author
exquad (registry namespace)
Repository
—
Site
thecablecode.com/developers
Version
1.103.0
Transport
Streamable HTTP
Authentication
None (observed by our test)
Server address
https://thecablecode.com/mcp Streamable HTTP
Tools
25
Categories
Images, audio and video
Last updated
27 Nov 2026
Published
27 Nov 2026

Badge for your README

Listed on L’Atlas

Free, for every entry. It links back to this entry and shows “tested OK” as long as our latest test succeeded.

MarkdownREADME.md
[![Listed on L’Atlas](https://latlas.dev/badge/fiche/io.github.exquad/thecablecode.svg?lang=en)](https://latlas.dev/en/mcp/io.github.exquad/thecablecode)
HTML
<a href="https://latlas.dev/en/mcp/io.github.exquad/thecablecode"><img src="https://latlas.dev/badge/fiche/io.github.exquad/thecablecode.svg?lang=en" alt="Listed on L’Atlas" height="20"></a>

Our tests

Every week: initialize then tools/list, without credentials, never calling a tool. Method

Address
https://thecablecode.com/mcp
Last result
OK 28 Nov 2026, 10:47
Response time
797 ms (initialize + tools/list)
Protocol version
2025-11-25
Announced name
thecablecode 1.103.0
Tools
25

History

DateResultResponseTools
28 Nov 2026, 10:47OK797 ms25

Exposed tools (25, from tools/list, 28 Nov 2026)

decode_cable_code

Decode a cable designation

Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. 5 free calls per caller per UTC day (with find_equivalents, overhead_conductor), then $0.10 USDC per call (x402).

ParameterTypeRequiredDescription
codestringyesA cable type designation as printed or listed.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAny of the site's 15 languages; default en.

design_cable

Design and size a power cable

Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-circuit ratings, optional files (XML, DXF, SVG, CSV, GLB, STEP, PDF). Deterministic, no LLM; nominal values. Notes: thecablecode://guide/design_cable. 2 free designs per caller per UTC day, then $0.50 USDC per design (x402).

ParameterTypeRequiredDescription
sentencestringnoThe cable in words (any site language) or a designation; what is not said takes a default, listed in the answer.
specobjectnoOr {voltage: "12/20", cores: 3, section: 95, metal, screen, insulation, sheath, armour, standard (a design_presets id), ...} or {lan: {category, shield, awg}}.
designobjectnoInstead of a sentence: the design field of an earlier answer, changed.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noLanguage of the answer's words; the sentence is read in any.
formatsarray<enum: "xml" | "dxf" | "svg" | "csv" | "glb" | "step" | "pdf">noFiles to include: xml, dxf, svg, csv, glb, step, pdf (datasheet).
installationobjectnoFor ratings.current: how the cable is installed; what is not given takes the defaults the answer lists.
fault_snumbernoFault duration for ratings.short_circuit, s (default 1).
loadobjectnoFor voltage_drop and sizing: {length_m (required), amps or kw, phases, volts, pf, limit_pct, conduit, formation}.
faultobjectnoFor cpc: {ka, seconds}, the adiabatic check up to 1 kV.
cpcobjectnoThe protective conductor check: {kind, system, device and device_a or ia_a, length_m, ...}.
necobjectnoNorth American wires: {ocpd_a, install, ambient_c, carrying, termination_c}: NEC ampacity and EGC; CSA designs by C22.1.
test_variantstringnoA national variant of the tests after installation; default the design standard's.

find_equivalents

Find a cable's equivalents in other countries

The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; never a statement of interchangeability. Notes: thecablecode://guide/find_equivalents. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).

ParameterTypeRequiredDescription
codestringnoA power cable designation with its size and voltage.
designobjectnoInstead of code: a design (the design field of a design_cable answer), compared with its own layers.
countrystringnoComma separated target countries: NL, SE, DK, NO, DE, GB, INT, EU, ES, IT, FR, PT, IN, CN, JP, AU, ZA, TH, US, CA. Default: all.
standardstringnoComma separated target standards, e.g. HD620-10J, BS6724, IEC, EN50618; default all. Every id: thecablecode://guide/find_equivalents.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noLanguage of the notes; default en.

overhead_conductor

Look up a bare overhead line conductor (EN 50182, ACSS)

A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table ("F.19"): stranding, areas, diameters, mass, strength and resistance as printed, with table and page. Deterministic, no LLM. Notes: thecablecode://guide/overhead_conductor. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).

ParameterTypeRequiredDescription
codestringnoA bare overhead conductor code: EN 50182:2001 4.5, the envelope's area and wire then the core's, e.g. "242-AL1/39-ST1A", "65-A20SA", "434-AL1/56-ST1A"; or an ACSS code by FprEN 50540 clause 4, e.g. "401-AL0/28-MEHST", read by its areas. Every Annex F country table that lists it answers.
tablestringnoInstead of code (or to narrow it): an EN 50182 Annex F country table (52 tables). Alone it answers every row of the table.
rowstringnoWith table: one conductor code of that table.
coreenum: "ST6A" | "EHST" | "MEHST" | "UHST" | "MUHST" | "20SA" | "20EHSA" | "14EHSA"noThe core wire of the ACSS build (FprEN 50540 clause 4): ST6A, EHST, MEHST, UHST, MUHST, 20SA, 20EHSA, 14EHSA; default ST6A, or an ACSS code's own core.

check_cable

Check a power cable against a standard

Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).

ParameterTypeRequiredDescription
designationstringnoA power cable designation with its size and voltage.
designobjectnoInstead of a designation: a thecablecode design v1 (the design field of a design_cable answer).
constructionobjectnoOr a datasheet's construction: {voltage: "12/20", cores, conductor: {metal, section}, core: [{kind, material, nominal, minimum}], common: [...], standards}, inside out.
standardstringno"auto" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i…

extract_datasheet

Read a cable datasheet into constructions

Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row. An LLM (Claude) reads, deciding nothing; with standard set the rules check each row. Notes: thecablecode://guide/extract_datasheet. Price (USDC, x402): a paid call from the first document: $2.00 in USDC per document, no free allowance.

ParameterTypeRequiredDescription
urlstringnoAn https link to a PDF datasheet or a datasheet web page.
textstringnoPasted datasheet, catalogue or tender text.
hintstringnoA designation or size to look for, e.g. "3x95/25 12/20 kV": only matching rows are returned.
standardstringnoAlso check every row: "auto" (the standards each row claims, else IEC 60502 by voltage) or rule sets, comma separated.

read_tender

Read a tender document: cables built, requirements, schedule, conflicts and gaps

Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up to about two minutes, then answers a poll link (GET /api/v1/tender/{job}); a PDF: POST /api/v1/tender. Notes: thecablecode://guide/read_tender. Always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages, USDC (x402).

ParameterTypeRequiredDescription
textstringyesThe document's text (a Word file turned into text); it counts one page per 1,700 characters begun.
hintstringnoA cable tag or a voltage to look for first.
langstringnoThe language of the schedule's parameter names: any of the site's 15 (en, tr, de, nl, sv, fr, es, da, no, fi, it, ro, pl, cs, ru). Default en.

write_specification

Write a cable specification and its required / offered schedule

Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), REQUIRED filled with sources, OFFERED left for the bidder. Deterministic, no LLM; a draft to check. Notes: thecablecode://guide/write_specification. Always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30, USDC (x402).

ParameterTypeRequiredDescription
sentencestringnoOne cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
installationobjectnoFor the current rating row, as design_cable takes it.
fault_snumbernoFault duration for the short-circuit rows, s (default 1).
drumstringnoThe drums section's line; absent: the bidder proposes.
cablesarray<object>noOr a project: cables, each {sentence | spec | design, installation, fault_s, drum}.
requirementsarray<string | object>noRequirement ids (rodent, uv-sunlight, flame-bunched, fire-resistance, longitudinal-watertight ...), or {id, option}; set on every cable. Every id and option: thecablecode://guide/write_specification or GET /api/v1/spec/requirements.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noLanguage of the specification; default en.

design_presets

List what the cable designer can build

What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the families a spec may name in spec.standard. Takes only lang. Free, no LLM.

ParameterTypeRequiredDescription
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noLanguage of the preset sentences and names; default en.

drum_fit

Find the cable drum a length needs

Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with barrel and load checks; reeling adds the NFPA 79 derating, lagging the handling block. Notes: thecablecode://guide/drum_fit. Free, outside the daily calls; deterministic, no LLM.

ParameterTypeRequiredDescription
odnumberyesCable outer diameter, mm (a flat cable: its larger side).
lengthnumbernoCable length to wind, m.
kgnumbernoCable mass, kg/km: adds weights and the load check.
kindenum: "flexible" | "lv-multi" | "lv-single" | "mv-multi" | "mv-single" | "hv" | "telecom" | "paper-lead"noCable kind for the smallest barrel; default lv-multi.
systemenum: "KTG" | "nordic-k" | "din" | "spanish" | "EU" | "NEMA" | "NA" | "TR" …noDrum family; default all.
maxintegernoMost drums of one size the length may be split over; default 1.
allowancenumbernoWound diameter over OD. Default 1.05.
freeboardnumbernoFreeboard to the flange rim, mm.
DnumbernoA drum by its dimensions: flange diameter, mm.
dnumbernoBarrel diameter, mm, less than D.
WnumbernoWinding width between the flanges, mm.
barrel_odnumbernoA bundle's lay-up diameter for the barrel check, mm; default od.
free_heightnumbernoWith D, d and W, a part-used drum: flange rim down to the cable top, mm.
poolnumber | number | booleannoWith length, 1: pooled sizes over makers (pools[]) instead of one row per drum.
reelingenum: "cylindrical" | "radial-vent" | "radial-closed"noA motor-driven reeling drum: adds the NFPA 79 (2024) derating.
layersintegernoWith reeling: the layers wound; default 1.
laggingenum: "none" | "full" | "export" | "spaced" | "cat" | "wrap" | "steel"noAdds the handling and storage block, with this lagging.
handlingnumber | number | booleanno1: the handling block with lagging none.
materialenum: "wood" | "plywood" | "steel" | "plastic" | "cardboard"noWith D, d and W: the drum's material for the handling block (default wood).
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noThe handling block's words: any of the site's 15 languages.

burial_depth

Minimum burial depth of a cable by country

Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes: thecablecode://guide/burial_depth.

ParameterTypeRequiredDescription
countryenum: "DE" | "TR" | "GB" | "FR" | "IT" | "PL" | "HK" | "US" …yesISO country code.
unumber | stringyesU in kV (1 for 0.6/1 kV, 20 for 12/20 kV) or Uo/U such as "0.6/1".
placeenum: "field" | "road" | "pavement"nofield (open ground, default), road or pavement.
methodenum: "direct" | "raceway"nodirect (default) or raceway (duct or conduit); the US and Australian rules tell them apart.

fire_class

Lowest fire class or listing a country asks for

The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 listing ladders. To read a printed class use decode_cable_code. Free, no LLM. Notes: thecablecode://guide/fire_class.

ParameterTypeRequiredDescription
countryenum: "DE" | "ES" | "FR" | "GB" | "IT" | "TR" | "US"yesISO country code of the installation.
placeenum: "escape" | "general" | "highrise" | "tunnel" | "hospital" | "datacentre" | "plenum" | "riser" …yesThe kind of building or space: escape (escape route), general, highrise, tunnel, hospital, datacentre, plenum, riser or railway.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

awg_metric

AWG or kcmil to mm² and back, by area and by resistance

AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Notes: thecablecode://guide/awg_metric.

ParameterTypeRequiredDescription
awgstringnoAn AWG or kcmil size: 12, 1/0, 4/0, 500.
mm2numbernoAn IEC 60228 class 2 size, mm².
metalenum: "Cu" | "Al"noCu (default) or Al.
knumbernoAn ICEA insulation constant K, MΩ·1000 ft at 15.6 °C.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

conduit_fill

NEC conduit fill: the smallest trade size

NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free, no LLM. Notes: thecablecode://guide/conduit_fill.

ParameterTypeRequiredDescription
racewayenum: "EMT" | "ENT" | "FMC" | "IMC" | "LFNCA" | "LFNCB" | "LFNCC" | "LFMC" …noTable 4 raceway type; default EMT.
nipplebooleannoA nipple up to 600 mm (Note 4, 60 %).
cablesarray<object>yesConductor rows: {type (THHN, XHHW, THW, RHW, RHW*, USE-2, THHN-5A ... bare, bare-solid), size (AWG or kcmil), count}, or a cable by its diameter {type: "od", od_mm, count}.

pull_cable

Cable pull: tensions and sidewall pressure

Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/pull_cable.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {route: [{kind: "straight", length, slope} | {kind: "bend", radius, angle, plane}], n, duct: {kind: "conduit", material, idMm} | {kind: "rollers"}, head, ...}
fullbooleannotrue: the whole answer (paid).
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.
pdfbooleannoFull mode: add the calculation sheet as pdf_base64.

tray_fill

NEC cable tray fill and ampacity

NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/tray_fill.

ParameterTypeRequiredDescription
inputobjectnoinput: {tray, width (mm), use, layout, ambientC, mv, cables: [{kind, size, metal, count, od, tempC, carrying}], ...}
fullbooleannotrue: the whole answer (paid).
itemsarray<object>noOr a list of {input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.
pdfbooleannoFull mode: add the calculation sheet as pdf_base64.

drum_loading

Drum loading plan for trucks and containers

How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/drum_loading.

ParameterTypeRequiredDescription
inputobjectnoinput: {vehicle, dt (transport diameter, mm), width (mm), gross (kg per drum), qty, ...}
fullbooleannotrue: the whole answer (paid).
itemsarray<object>noOr a list of {input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

cold_weather_check

Cold-weather laying check

A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/cold_weather_check.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {place: a GeoNames id (number) or "lat, lon", month: 1 to 12}
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

mv_electrical

Electrical values of an MV or HV design

MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/mv_electrical.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {freq: 50 | 60, trefoilMm?, flatMm?} (axis spacing, mm; absent: touching)
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

economic_size

Economic size of an MV or HV design

Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/economic_size.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {amps, hours, mu, price (per kWh), years, interest (%), lengthM, ambientC, ...}
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

commissioning_sheet

Commissioning sheet (PDF)

The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/commissioning_sheet.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {tests?, variant?, length? (m)}
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

cable_prep

Cable end preparation

End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/cable_prep.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {pollution?: a to e, fittings?: {formation, spacingMm, currentA, ...}, ...}
fullbooleannotrue: the whole answer (paid).
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.
pdfbooleannoFull mode: add the calculation sheet as pdf_base64.

iec60287_rating

IEC 60287 rating of one MV or HV circuit

IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/iec60287_rating.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {laying: buried | duct | air, formation: trefoil | flat, bonding, depthM?, soil?, groundC?, airC?, cycle?, emergency?, ...}
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

degassing_time

XLPE degassing time estimate

Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {tempC? (default 70), target? (share left, default 0.1), calibration?, ...}
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

equivalence_report

IEC against NEC / UL equivalence report

An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/equivalence_report.

ParameterTypeRequiredDescription
sentencestringnoThe cable, as design_cable takes it.
specobjectnoOr a design_cable spec.
designobjectnoOr a design_cable design.
inputobjectnoinput: {format?: md | txt (the report file; default md)}
itemsarray<object>noOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …noAnswer language; default en.

Client compatibility

Based on the transports each client documents as supported; this is not a live test inside the client.

ClientDocumented transportsThis serverSource
Claude Codestdio Streamable HTTP SSEtransport accepteddoc
Claude (claude.ai, Claude Desktop, Cowork)stdio Streamable HTTP SSEtransport accepteddoc
ChatGPT (serveurs MCP personnalisés / plugins)Streamable HTTP SSEtransport accepteddoc
Cursorstdio Streamable HTTP SSEtransport accepteddoc
VS Code (GitHub Copilot)stdio Streamable HTTP SSEtransport accepteddoc
Windsurf (documentation redirigée vers Devin Local / Devin CLI)stdio Streamable HTTP SSEtransport accepteddoc
Gemini CLIstdio Streamable HTTP SSEtransport accepteddoc
OpenAI Codex (CLI, extension IDE, app)stdio Streamable HTTPtransport accepteddoc

Ready-to-copy configs

Remote address used: https://thecablecode.com/mcp. Formats taken from each client’s documentation.

Claude Code
claude mcp add --transport http thecablecode https://thecablecode.com/mcp
Claude (claude.ai, Claude Desktop, Cowork)
Customize > Connectors > + Add > Add custom connector ; Name : thecablecode ; URL : https://thecablecode.com/mcp
ChatGPT (serveurs MCP personnalisés / plugins)
chatgpt.com/plugins > + > Add custom MCP server ; Name : thecablecode ; Server URL : https://thecablecode.com/mcp ; Create as a plugin
Cursor.cursor/mcp.json (projet) ou ~/.cursor/mcp.json (global)
{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
VS Code (GitHub Copilot).mcp.json à la racine du workspace, ou ~/.copilot/mcp-config.json ($COPILOT_HOME/mcp-config.json)
{
  "mcpServers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp",
      "tools": ["*"]
    }
  }
}
Windsurf (documentation redirigée vers Devin Local / Devin CLI).devin/mcp_config.json (projet), .devin/mcp_config.local.json (local), ~/.config/devin/mcp_config.json (utilisateur)
{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
Gemini CLI~/.gemini/settings.json (utilisateur) ou .gemini/settings.json (projet)
{
  "mcpServers": {
    "thecablecode": {
      "httpUrl": "https://thecablecode.com/mcp"
    }
  }
}
OpenAI Codex (CLI, extension IDE, app)~/.codex/config.toml (ou .codex/config.toml pour un projet de confiance)
[mcp_servers.thecablecode]
url = "https://thecablecode.com/mcp"

Source : Registre officiel MCP · retrieved 29 Nov 2026. L’Atlas adds no data beyond this source and its own tests.