L'Atlas / Serveurs MCP / The Cable Code

The Cable Code

io.github.exquad/thecablecode

Serveur MCP OK

Faire examiner Voir les tarifs

Decode cables in 71 coding systems; design, rate, check, find equivalents; drums, laying, fire.

Fiche technique

Auteur
exquad (espace de noms du registre)
Dépôt
—
Site
thecablecode.com/developers
Version
1.103.0
Transport
Streamable HTTP
Authentification
Aucune (constatée par notre test)
Adresse du serveur
https://thecablecode.com/mcp Streamable HTTP
Outils
25
Catégories
Images, audio et vidéo
Dernière mise à jour
27 nov. 2026
Publication
27 nov. 2026

Badge pour votre README

Référencé sur L’Atlas

Gratuit, pour toute fiche. Il renvoie vers cette fiche et affiche « testé OK » tant que notre dernier test est réussi.

MarkdownREADME.md
[![Référencé sur L’Atlas](https://latlas.dev/badge/fiche/io.github.exquad/thecablecode.svg)](https://latlas.dev/mcp/io.github.exquad/thecablecode)
HTML
<a href="https://latlas.dev/mcp/io.github.exquad/thecablecode"><img src="https://latlas.dev/badge/fiche/io.github.exquad/thecablecode.svg" alt="Référencé sur L’Atlas" height="20"></a>

Nos tests

Chaque semaine : initialize puis tools/list, sans identifiant, sans jamais appeler d’outil. Méthode

Adresse
https://thecablecode.com/mcp
Dernier résultat
OK 28 nov. 2026, 10:47
Temps de réponse
797 ms (initialize + tools/list)
Version du protocole
2025-11-25
Nom annoncé
thecablecode 1.103.0
Outils
25

Historique

DateRésultatRéponseOutils
28 nov. 2026, 10:47OK797 ms25

Outils exposés (25, réponse à tools/list, 28 nov. 2026)

decode_cable_code

Decode a cable designation

Decode a cable type designation (DIN VDE, HAR, BS/IEC, NEC, TS, UTE, CEI-UNEL and 64 more of its 71 coding systems, plus LAN and fibre) into its layers: conductor, insulation, screen, armour, sheath, with the source behind each symbol. Deterministic, no LLM. 5 free calls per caller per UTC day (with find_equivalents, overhead_conductor), then $0.10 USDC per call (x402).

ParamètreTypeRequisDescription
codestringouiA cable type designation as printed or listed.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAny of the site's 15 languages; default en.

design_cable

Design and size a power cable

Design and size a cable (power, control, LAN, coaxial, fibre) from a sentence in any site language, a designation, a spec or a design: each layer with its standard and source, diameter, weight, designation, current, voltage drop and short-circuit ratings, optional files (XML, DXF, SVG, CSV, GLB, STEP, PDF). Deterministic, no LLM; nominal values. Notes: thecablecode://guide/design_cable. 2 free designs per caller per UTC day, then $0.50 USDC per design (x402).

ParamètreTypeRequisDescription
sentencestringnonThe cable in words (any site language) or a designation; what is not said takes a default, listed in the answer.
specobjectnonOr {voltage: "12/20", cores: 3, section: 95, metal, screen, insulation, sheath, armour, standard (a design_presets id), ...} or {lan: {category, shield, awg}}.
designobjectnonInstead of a sentence: the design field of an earlier answer, changed.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonLanguage of the answer's words; the sentence is read in any.
formatsarray<enum: "xml" | "dxf" | "svg" | "csv" | "glb" | "step" | "pdf">nonFiles to include: xml, dxf, svg, csv, glb, step, pdf (datasheet).
installationobjectnonFor ratings.current: how the cable is installed; what is not given takes the defaults the answer lists.
fault_snumbernonFault duration for ratings.short_circuit, s (default 1).
loadobjectnonFor voltage_drop and sizing: {length_m (required), amps or kw, phases, volts, pf, limit_pct, conduit, formation}.
faultobjectnonFor cpc: {ka, seconds}, the adiabatic check up to 1 kV.
cpcobjectnonThe protective conductor check: {kind, system, device and device_a or ia_a, length_m, ...}.
necobjectnonNorth American wires: {ocpd_a, install, ambient_c, carrying, termination_c}: NEC ampacity and EGC; CSA designs by C22.1.
test_variantstringnonA national variant of the tests after installation; default the design standard's.

find_equivalents

Find a cable's equivalents in other countries

The same power cable under other countries' standards (IEC 60502, HD 603, HD 620, BS, EN 50618, HD 627), rebuilt and compared layer by layer with sources: equivalent, close (the differences) or none (the reason). Deterministic, no LLM; never a statement of interchangeability. Notes: thecablecode://guide/find_equivalents. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).

ParamètreTypeRequisDescription
codestringnonA power cable designation with its size and voltage.
designobjectnonInstead of code: a design (the design field of a design_cable answer), compared with its own layers.
countrystringnonComma separated target countries: NL, SE, DK, NO, DE, GB, INT, EU, ES, IT, FR, PT, IN, CN, JP, AU, ZA, TH, US, CA. Default: all.
standardstringnonComma separated target standards, e.g. HD620-10J, BS6724, IEC, EN50618; default all. Every id: thecablecode://guide/find_equivalents.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonLanguage of the notes; default en.

overhead_conductor

Look up a bare overhead line conductor (EN 50182, ACSS)

A bare overhead line conductor (AAC, AAAC, ACSR, ACSS) by its code ("242-AL1/39-ST1A", EN 50182; "401-AL0/28-MEHST", FprEN 50540) or an EN 50182 Annex F table ("F.19"): stranding, areas, diameters, mass, strength and resistance as printed, with table and page. Deterministic, no LLM. Notes: thecablecode://guide/overhead_conductor. The decodes' 5 free calls per caller per UTC day, then $0.10 USDC per call (x402).

ParamètreTypeRequisDescription
codestringnonA bare overhead conductor code: EN 50182:2001 4.5, the envelope's area and wire then the core's, e.g. "242-AL1/39-ST1A", "65-A20SA", "434-AL1/56-ST1A"; or an ACSS code by FprEN 50540 clause 4, e.g. "401-AL0/28-MEHST", read by its areas. Every Annex F country table that lists it answers.
tablestringnonInstead of code (or to narrow it): an EN 50182 Annex F country table (52 tables). Alone it answers every row of the table.
rowstringnonWith table: one conductor code of that table.
coreenum: "ST6A" | "EHST" | "MEHST" | "UHST" | "MUHST" | "20SA" | "20EHSA" | "14EHSA"nonThe core wire of the ACSS build (FprEN 50540 clause 4): ST6A, EHST, MEHST, UHST, MUHST, 20SA, 20EHSA, 14EHSA; default ST6A, or an ACSS code's own core.

check_cable

Check a power cable against a standard

Check a power cable (a designation with size and voltage, a design, or a datasheet's construction) against a standard's nominal rules: each rule with required, found, pass / fail / not checkable and its source. Deterministic, no LLM; not a certificate or a type test. Notes: thecablecode://guide/check_cable. 2 free checks per caller per UTC day, then $0.50 USDC per check (x402).

ParamètreTypeRequisDescription
designationstringnonA power cable designation with its size and voltage.
designobjectnonInstead of a designation: a thecablecode design v1 (the design field of a design_cable answer).
constructionobjectnonOr a datasheet's construction: {voltage: "12/20", cores, conductor: {metal, section}, core: [{kind, material, nominal, minimum}], common: [...], standards}, inside out.
standardstringnon"auto" (default: the standards the input claims) or rule sets, comma separated, at most 4: iec-60502-1-2004, iec-60502-2-2014, iec-60228-2023, hd-603-3-g, hd-603-5-g, hd-620-10-j, hd-620-10-m, hd-620-10-d, hd-620-10-c, hd-620-10-k, hd-620-10-e1, hd-620-10-e2, hd-620-10-i1, hd-620-10-i2, hd-620-10-i…

extract_datasheet

Read a cable datasheet into constructions

Read a power cable datasheet (an https link to a PDF or page, or pasted text) into constructions: each size's voltage, cores, conductor, layers with nominal and smallest thickness, screen, armour, diameters and standards, with page and row. An LLM (Claude) reads, deciding nothing; with standard set the rules check each row. Notes: thecablecode://guide/extract_datasheet. Price (USDC, x402): a paid call from the first document: $2.00 in USDC per document, no free allowance.

ParamètreTypeRequisDescription
urlstringnonAn https link to a PDF datasheet or a datasheet web page.
textstringnonPasted datasheet, catalogue or tender text.
hintstringnonA designation or size to look for, e.g. "3x95/25 12/20 kV": only matching rows are returned.
standardstringnonAlso check every row: "auto" (the standards each row claims, else IEC 60502 by voltage) or rule sets, comma separated.

read_tender

Read a tender document: cables built, requirements, schedule, conflicts and gaps

Read a tender or project document's text into its cables (built and checked by the rules), the required / offered schedule, requirements, conflicts and missing sections, with pages. An LLM (Claude) copies values, deciding nothing. Waits up to about two minutes, then answers a poll link (GET /api/v1/tender/{job}); a PDF: POST /api/v1/tender. Notes: thecablecode://guide/read_tender. Always paid: $4.00 up to 20 pages, $2.00 for each further 10 pages begun, up to 80 pages, USDC (x402).

ParamètreTypeRequisDescription
textstringouiThe document's text (a Word file turned into text); it counts one page per 1,700 characters begun.
hintstringnonA cable tag or a voltage to look for first.
langstringnonThe language of the schedule's parameter names: any of the site's 15 (en, tr, de, nl, sv, fr, es, da, no, fi, it, ro, pl, cs, ru). Default en.

write_specification

Write a cable specification and its required / offered schedule

Write the cable specification for a tender, one cable or a project, each as design_cable takes it, with the project's requirements: the specification in tender order (Markdown and text) and the required / offered schedule (CSV and JSON), REQUIRED filled with sources, OFFERED left for the bidder. Deterministic, no LLM; a draft to check. Notes: thecablecode://guide/write_specification. Always paid: $2.00 for the first cable, $0.50 for each further cable in the same call, up to 30, USDC (x402).

ParamètreTypeRequisDescription
sentencestringnonOne cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
installationobjectnonFor the current rating row, as design_cable takes it.
fault_snumbernonFault duration for the short-circuit rows, s (default 1).
drumstringnonThe drums section's line; absent: the bidder proposes.
cablesarray<object>nonOr a project: cables, each {sentence | spec | design, installation, fault_s, drum}.
requirementsarray<string | object>nonRequirement ids (rodent, uv-sunlight, flame-bunched, fire-resistance, longitudinal-watertight ...), or {id, option}; set on every cable. Every id and option: thecablecode://guide/write_specification or GET /api/v1/spec/requirements.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonLanguage of the specification; default en.

design_presets

List what the cable designer can build

What design_cable builds: presets[] (power, MV, HV, North American, building wire, cords, control, LAN, coaxial, fibre), each with the sentence that builds it, its designation, voltage, cores, section and metal; and spec_standards[], the families a spec may name in spec.standard. Takes only lang. Free, no LLM.

ParamètreTypeRequisDescription
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonLanguage of the preset sentences and names; default en.

drum_fit

Find the cable drum a length needs

Which cable drum (reel) a length needs (od, length), or what one drum takes (od, D, d, W): nested whole layers on 1.05 x OD under a freeboard, over KTG, Nordic K, DIN, Spanish, NEMA, Turkish, IS 10418 and makers' drums with sources, with barrel and load checks; reeling adds the NFPA 79 derating, lagging the handling block. Notes: thecablecode://guide/drum_fit. Free, outside the daily calls; deterministic, no LLM.

ParamètreTypeRequisDescription
odnumberouiCable outer diameter, mm (a flat cable: its larger side).
lengthnumbernonCable length to wind, m.
kgnumbernonCable mass, kg/km: adds weights and the load check.
kindenum: "flexible" | "lv-multi" | "lv-single" | "mv-multi" | "mv-single" | "hv" | "telecom" | "paper-lead"nonCable kind for the smallest barrel; default lv-multi.
systemenum: "KTG" | "nordic-k" | "din" | "spanish" | "EU" | "NEMA" | "NA" | "TR" …nonDrum family; default all.
maxintegernonMost drums of one size the length may be split over; default 1.
allowancenumbernonWound diameter over OD. Default 1.05.
freeboardnumbernonFreeboard to the flange rim, mm.
DnumbernonA drum by its dimensions: flange diameter, mm.
dnumbernonBarrel diameter, mm, less than D.
WnumbernonWinding width between the flanges, mm.
barrel_odnumbernonA bundle's lay-up diameter for the barrel check, mm; default od.
free_heightnumbernonWith D, d and W, a part-used drum: flange rim down to the cable top, mm.
poolnumber | number | booleannonWith length, 1: pooled sizes over makers (pools[]) instead of one row per drum.
reelingenum: "cylindrical" | "radial-vent" | "radial-closed"nonA motor-driven reeling drum: adds the NFPA 79 (2024) derating.
layersintegernonWith reeling: the layers wound; default 1.
laggingenum: "none" | "full" | "export" | "spaced" | "cat" | "wrap" | "steel"nonAdds the handling and storage block, with this lagging.
handlingnumber | number | booleannon1: the handling block with lagging none.
materialenum: "wood" | "plywood" | "steel" | "plastic" | "cardboard"nonWith D, d and W: the drum's material for the handling block (default wood).
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonThe handling block's words: any of the site's 15 languages.

burial_depth

Minimum burial depth of a cable by country

Minimum burial cover of a power cable by country, voltage and place (open ground, road, pavement; direct or in a raceway for US and AU), from that country's rule with its source and seen level, or null with the reason. Free, no LLM. Notes: thecablecode://guide/burial_depth.

ParamètreTypeRequisDescription
countryenum: "DE" | "TR" | "GB" | "FR" | "IT" | "PL" | "HK" | "US" …ouiISO country code.
unumber | stringouiU in kV (1 for 0.6/1 kV, 20 for 12/20 kV) or Uo/U such as "0.6/1".
placeenum: "field" | "road" | "pavement"nonfield (open ground, default), road or pavement.
methodenum: "direct" | "raceway"nondirect (default) or raceway (duct or conduit); the US and Australian rules tell them apart.

fire_class

Lowest fire class or listing a country asks for

The lowest fire class or listing a country asks for in a kind of building or space (DE, ES, FR, GB, IT, TR, US: escape route, high-rise, tunnel, hospital, plenum ...), the rule lines with sources and seen levels; the US NEC Article 722 listing ladders. To read a printed class use decode_cable_code. Free, no LLM. Notes: thecablecode://guide/fire_class.

ParamètreTypeRequisDescription
countryenum: "DE" | "ES" | "FR" | "GB" | "IT" | "TR" | "US"ouiISO country code of the installation.
placeenum: "escape" | "general" | "highrise" | "tunnel" | "hospital" | "datacentre" | "plenum" | "riser" …ouiThe kind of building or space: escape (escape route), general, highrise, tunnel, hospital, datacentre, plenum, riser or railway.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

awg_metric

AWG or kcmil to mm² and back, by area and by resistance

AWG / kcmil against IEC 60228 mm2, both ways, by area and by maximum resistance at 20 °C, each size with its resistance and source; with k, the ICEA insulation constant in MΩ·km. Send awg or mm2, metal Cu (default) or Al. Free, no LLM. Notes: thecablecode://guide/awg_metric.

ParamètreTypeRequisDescription
awgstringnonAn AWG or kcmil size: 12, 1/0, 4/0, 500.
mm2numbernonAn IEC 60228 class 2 size, mm².
metalenum: "Cu" | "Al"nonCu (default) or Al.
knumbernonAn ICEA insulation constant K, MΩ·1000 ft at 15.6 °C.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

conduit_fill

NEC conduit fill: the smallest trade size

NEC Chapter 9 conduit fill: the smallest trade size of a raceway type (EMT, IMC, RMC, PVC, ENT, FMC, LFNC, LFMC, HDPE ...) for a list of conductors or cables, against Table 1's fill limits, with the jam ratio; each area with its table. Free, no LLM. Notes: thecablecode://guide/conduit_fill.

ParamètreTypeRequisDescription
racewayenum: "EMT" | "ENT" | "FMC" | "IMC" | "LFNCA" | "LFNCB" | "LFNCC" | "LFMC" …nonTable 4 raceway type; default EMT.
nipplebooleannonA nipple up to 600 mm (Note 4, 60 %).
cablesarray<object>ouiConductor rows: {type (THHN, XHHW, THW, RHW, RHW*, USE-2, THHN-5A ... bare, bare-solid), size (AWG or kcmil), count}, or a cable by its diameter {type: "od", od_mm, count}.

pull_cable

Cable pull: tensions and sidewall pressure

Pull a cable through straights and bends (conduit or rollers): tension per segment from either end, sidewall pressure per bend, jam ratio and fill, against the allowable values with sources. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/pull_cable.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {route: [{kind: "straight", length, slope} | {kind: "bend", radius, angle, plane}], n, duct: {kind: "conduit", material, idMm} | {kind: "rollers"}, head, ...}
fullbooleannontrue: the whole answer (paid).
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.
pdfbooleannonFull mode: add the calculation sheet as pdf_base64.

tray_fill

NEC cable tray fill and ampacity

NEC cable tray fill (392.22) and each cable's derated ampacity (392.80), up to 2000 V and Type MV: pass or fail. A conduit: conduit_fill (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/tray_fill.

ParamètreTypeRequisDescription
inputobjectnoninput: {tray, width (mm), use, layout, ambientC, mv, cables: [{kind, size, metal, count, od, tempC, carrying}], ...}
fullbooleannontrue: the whole answer (paid).
itemsarray<object>nonOr a list of {input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.
pdfbooleannonFull mode: add the calculation sheet as pdf_base64.

drum_loading

Drum loading plan for trucks and containers

How filled drums travel: vehicles needed by space and payload, rows, chocks, and EN 12195-1 securing (blocking, lashings), each vehicle compared, with sources. Choose the drum with drum_fit (free). $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/drum_loading.

ParamètreTypeRequisDescription
inputobjectnoninput: {vehicle, dt (transport diameter, mm), width (mm), gross (kg per drum), qty, ...}
fullbooleannontrue: the whole answer (paid).
itemsarray<object>nonOr a list of {input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

cold_weather_check

Cold-weather laying check

A place's long-term mean daily minimum in a month (NASA POWER, stored) against the design's minimum laying temperature: comfortable, marginal, prewarm or unknown. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/cold_weather_check.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {place: a GeoNames id (number) or "lat, lon", month: 1 to 12}
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

mv_electrical

Electrical values of an MV or HV design

MV or HV design: capacitance, charging current, reactance, a.c. resistance (IEC 60287-1-1), dielectric loss and impulse levels (IEC 60502-2), each with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/mv_electrical.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {freq: 50 | 60, trefoilMm?, flatMm?} (axis spacing, mm; absent: touching)
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

economic_size

Economic size of an MV or HV design

Economic conductor size of an MV or HV design (IEC 60287-3-2): losses and their present cost for this size and the two sizes up, and the payback, each step with its source. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/economic_size.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {amps, hours, mu, price (per kWh), years, interest (%), lengthM, ambientC, ...}
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

commissioning_sheet

Commissioning sheet (PDF)

The tests after installation for a design (IEC 60502-2, IEC 60840, IEC 62067, HD 620, BS, IEEE 400.2), each with voltage, duration and source, as a PDF to record results in. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/commissioning_sheet.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {tests?, variant?, length? (m)}
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

cable_prep

Cable end preparation

End preparation of an LV, MV or HV cable for a termination or joint: cut steps with the design's depths, makers' cut-back lengths (typical), lug, accessory kinds, outdoor creepage (IEC TS 60815-3), glands and cleats. $0.50 USDC per calculation (x402); the verdict alone (no full) is free within the designs' 2 calls per caller per UTC day. Notes: thecablecode://guide/cable_prep.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {pollution?: a to e, fittings?: {formation, spacingMm, currentA, ...}, ...}
fullbooleannontrue: the whole answer (paid).
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.
pdfbooleannonFull mode: add the calculation sheet as pdf_base64.

iec60287_rating

IEC 60287 rating of one MV or HV circuit

IEC 60287 rating of one MV or HV circuit at the site sent (buried, ducts or air), each step with clause and page; optional IEC 60853 cyclic and emergency ratings, banks, troughs, crossings. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/iec60287_rating.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {laying: buried | duct | air, formation: trefoil | flat, bonding, depthM?, soil?, groundC?, airC?, cycle?, emergency?, ...}
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

degassing_time

XLPE degassing time estimate

Days an XLPE MV or HV core needs in the oven before its sheath (Fick diffusion, published coefficients): a band, not a standard's result; the AEIC CS8-20 wait beside it up to 46 kV. $5.00 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/degassing_time.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {tempC? (default 70), target? (share left, default 0.1), calibration?, ...}
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

equivalence_report

IEC against NEC / UL equivalence report

An IEC cable in mm2 against its North American counterpart (XHHW-2, RHW-2, THHN or MV-105), value by value with sources, as lines and a report file; never a statement of interchangeability. $0.50 USDC per calculation (x402), no free allowance. Notes: thecablecode://guide/equivalence_report.

ParamètreTypeRequisDescription
sentencestringnonThe cable, as design_cable takes it.
specobjectnonOr a design_cable spec.
designobjectnonOr a design_cable design.
inputobjectnoninput: {format?: md | txt (the report file; default md)}
itemsarray<object>nonOr a list of {sentence | spec | design, input}, paid per item.
langenum: "en" | "tr" | "de" | "nl" | "sv" | "fr" | "es" | "da" …nonAnswer language; default en.

Compatibilité clients

Selon les transports que chaque client déclare accepter dans sa documentation officielle ; ce n’est pas un essai réel dans le client.

ClientTransports documentésCe serveurSource
Claude Codestdio Streamable HTTP SSEtransport acceptédoc
Claude (claude.ai, Claude Desktop, Cowork)stdio Streamable HTTP SSEtransport acceptédoc
ChatGPT (serveurs MCP personnalisés / plugins)Streamable HTTP SSEtransport acceptédoc
Cursorstdio Streamable HTTP SSEtransport acceptédoc
VS Code (GitHub Copilot)stdio Streamable HTTP SSEtransport acceptédoc
Windsurf (documentation redirigée vers Devin Local / Devin CLI)stdio Streamable HTTP SSEtransport acceptédoc
Gemini CLIstdio Streamable HTTP SSEtransport acceptédoc
OpenAI Codex (CLI, extension IDE, app)stdio Streamable HTTPtransport acceptédoc

Configs prêtes à copier

Adresse distante utilisée : https://thecablecode.com/mcp. Formats repris de la documentation de chaque client.

Claude Code
claude mcp add --transport http thecablecode https://thecablecode.com/mcp
Claude (claude.ai, Claude Desktop, Cowork)
Customize > Connectors > + Add > Add custom connector ; Name : thecablecode ; URL : https://thecablecode.com/mcp
ChatGPT (serveurs MCP personnalisés / plugins)
chatgpt.com/plugins > + > Add custom MCP server ; Name : thecablecode ; Server URL : https://thecablecode.com/mcp ; Create as a plugin
Cursor.cursor/mcp.json (projet) ou ~/.cursor/mcp.json (global)
{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
VS Code (GitHub Copilot).mcp.json à la racine du workspace, ou ~/.copilot/mcp-config.json ($COPILOT_HOME/mcp-config.json)
{
  "mcpServers": {
    "thecablecode": {
      "type": "http",
      "url": "https://thecablecode.com/mcp",
      "tools": ["*"]
    }
  }
}
Windsurf (documentation redirigée vers Devin Local / Devin CLI).devin/mcp_config.json (projet), .devin/mcp_config.local.json (local), ~/.config/devin/mcp_config.json (utilisateur)
{
  "mcpServers": {
    "thecablecode": {
      "url": "https://thecablecode.com/mcp"
    }
  }
}
Gemini CLI~/.gemini/settings.json (utilisateur) ou .gemini/settings.json (projet)
{
  "mcpServers": {
    "thecablecode": {
      "httpUrl": "https://thecablecode.com/mcp"
    }
  }
}
OpenAI Codex (CLI, extension IDE, app)~/.codex/config.toml (ou .codex/config.toml pour un projet de confiance)
[mcp_servers.thecablecode]
url = "https://thecablecode.com/mcp"

Source : Registre officiel MCP · relevé le 29 nov. 2026. L’Atlas n’ajoute aucune donnée qui ne vienne de cette source ou de ses propres tests.